Voltage 9 to 30 VDC
Current Supply 50 mA maximum
Output Signal Resolution 100 pulses per channel per revolution, unscaled see table
Pulse Timing Nominal 50% on and 50% off
Operating Temperature Range -40 to 176 °F (-40 to 80 °C)
Humidity Range 0-100%, non-condensing
Pricing available on request — ACG will respond within 24 hours with a full proposal.
Send requirement directly
Voltage 9 to 30 VDC
Current Supply 50 mA maximum
Output Signal Resolution 100 pulses per channel per revolution, unscaled see table
Pulse Timing Nominal 50% on and 50% off
Operating Temperature Range -40 to 176 °F (-40 to 80 °C)
Humidity Range 0-100%, non-condensing
Shock 50 Gs for 10 ms
Vibration 1 G at 10-150 Hz
Pulse Transmission Distance 5,000 feet (1,524 meters)
SKU LCPOD3
Manufacturer Liquid Controls
Weight 3.00 LBS

Liquid Controls POD3 Pulse Output Device The Liquid Controls Pulse Output Device (POD) converts the rotary motion of the Liquid Controls Positive Displacement Flowmeter into electronic pulses. This allows the meter to interface with a wide variety of electronic monitoring devices and control equipment. The POD operates in standard and bidirectional flow applications. The POD mounts directly to the front cover of any Liquid Controls meter in place of the packing gland. The motion of the meter’s blocking rotor is magnetically coupled through a stainless steel wall to the electronics compartment of the POD. This eliminates the dynamic seal of the packing gland and isolates the electronics from the process fluid in the meter. The electronic pulses generated by the POD is easily adapted to a wide variety of electronic monitoring devices and control equipment. Features Glandless drive No dynamic seals to fail or leak Unscaled pulse output Easily adapts to remote totalizers, batch controllers, computers, PLC’s and other pulse receiving devices. No amplifier or signal conditioner required Wetted parts 316 stainless steel or equivalent Meets current environmental standards: Weights & Measures; NEMA 4X; Class I, Div. 1 & 2, Groups C & D; DNV 11 ATEX 01600X and IECEx DNV 11.0012X 350 PSI (24 BAR) working pressure rating Burst pressure exceeds 1,750 PSI (121 BAR) ½ in. NPT conduit port with a removable screw terminal block Specifications Voltage: 9 to 30 VDC Current Supply: 50 mA maximum Output Signal Resolution: 100 pulses per channel per revolution, unscaled see table Square Wave: Single channel output channel A or channel B Quadrature channel output channel A and channel B Pulse Timing: Nominal 50% on and 50% off Rise/Fall Time of Pulse: Operating Temperature Range: -40 to 176 °F (-40 to 80 °C) Output: Current sinking100 mA maximum in “ON” state V+ supply @ 2.2 KΩ in “OFF” state. Optional Open Drain FET (Field Effect Transistor) FET rating (drain to source voltage) 30 VDC maximum Humidity Range: 0-100%, non-condensing Shock: 50 Gs for 10 ms Vibration: 1 G at 10-150 Hz Pulse Transmission Distance: 5,000 feet (1,524 meters) Electromagnetic Compatibility (EMI, RFI, etc.): EU Directive 2004/108/EC (EMC) IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-17 IEC 61000-4-29 IEC 61000-6-3 ISO 7637-2 Downloads Pulse Output Device (POD) Installation & Parts (PDF Download)

This is your item. Ready to proceed?

Add it to your RFQ basket or submit your requirement directly — ACG will respond within 24 hours with pricing, availability and delivery options.

RFQ Basket

Your RFQ basket is empty

Browse the catalogue and add items to build your requirement list Browse catalogue
Search