PART OF THE NOVA PLATFORM · KAMPALA, UGANDA · MALATYA, TURKEY · GLASGOW, SCOTLAND
EMERSON FISHER N100 Series Bypass Valve GRID_FIN100A081
Emerson Fisher

EMERSON FISHER N100 Series Bypass Valve GRID_FIN100A081

Part No. GRID_FIN100A081 Unit EA
Pump Size 2 - 4 in.
Body Size 1 - 2 in. FNPT
PSID Setting 50 - 115 psig (3.4 - 7.9 bar)
PSID Range 25 to 150 psig (1.7 to 10.3 bar)
Maximum Inlet Pressure 400 psig (27.6 bar)
Temperature Capabilities -20 to 160°F (-29 to 71°C)
Pricing available on request — ACG will respond within 24 hours with a full proposal.
Send requirement directly
Pump Size 2 - 4 in.
Body Size 1 - 2 in. FNPT
PSID Setting 50 - 115 psig (3.4 - 7.9 bar)
PSID Range 25 to 150 psig (1.7 to 10.3 bar)
Maximum Inlet Pressure 400 psig (27.6 bar)
Temperature Capabilities -20 to 160°F (-29 to 71°C)
Warranty 10 Years
SKU GRID_FIN100A081
Manufacturer Emerson Fisher
Size 1 in.
Weight 11.00 LBS

Emerson Fisher's N100 Series is designed for bypass on 2 to 4 in. size pumps, the N100 Series is widely used on both LPG and Anhydrous Ammonia (NH‚ƒ) applications. The throttling action of the N100 series allows only surplus pump discharge to be returned to the tank. A venturi flow passage gives a boost effect, permitting a greater valve opening for increased flow at the lower pressure build-ups when bypassing full pump output. These features help to give rapid, stable liquid transfer and reduce dangerous pressure pulsations. The valves contain only one moving part- the piston style inner valve. An external sensing line is not required because tank pressure registers through a hole in the inner valve. Complete field servicing can be made without removing the valve from the piping.This product is backed by a 10 year warranty. Note: All N100 Series bodies have 1/4 in. FNPT tapped and plugged boss on the side inlet for either a pressure gauge or a hydrostatic relief valve and have a temperature rating of -20 to 160°F (-29 to 71°C) Features Closing Cap Pressure Sensing Orifice Piston Inner Valve Exclusive Venturi Passage UL Listed (4 in. Sizes are not UL Listed) Specifications Pump Size: 2 - 4 in. Body Size: 1 - 2 in. FNPT PSID Setting: 50 - 115 psig (3.4 - 7.9 bar) PSID Range: 25 to 150 psig (1.7 to 10.3 bar) Maximum Inlet Pressure: 400 psig (27.6 bar) Temperature Capabilities: -20 to 160°F (-29 to 71°C)Warranty: 10 Years Downloads Instruction Manual (PDF Download) Replacement Parts Sheet (PDF Download) N100 Series Bypass Valve Schematic (PDF Download)

This is your item. Ready to proceed?

Add it to your RFQ basket or submit your requirement directly — ACG will respond within 24 hours with pricing, availability and delivery options.

RFQ Basket

Your RFQ basket is empty

Browse the catalogue and add items to build your requirement list Browse catalogue