| Accuracy (%of reading) - Meter | ± 0.2% with optional RT14 with non-linearity correction |
| Repeatability - Meter | +/- 0.03% |
| Metric Operating Fluid Temp - Min | -40° |
| Metric Operating Fluid Temp - Max | 80° |
| Metric Operating Fluid Temp - Units | C |
| Std Operating Fluid Temp - Max | 176° |
| Std Operating Fluid Temp - Min | -40° |
| Std Operating Fluid Temp - Units | F |
| Std Pressure Rating | 174 |
| Std Pressure Rating - Units | psi |
| Metric Pressure Rating | 12 |
| Metric Pressure Rating - Units | bar |
| Safety Classification | Safe Area Only |
| Std Flow Range - Min | 2.6 |
| Std Flow Range - Max | 40 |
| Std Flow Range - Units | GPM |
| Metric Flow Range - Min | 10 |
| Metric Flow Range - Max | 150 |
| Metric Flow Range - Units | L/min |
| Technology | Oval Gear |
Description1-inch PPS Oval Gear Flow Meter with NPT Fittings. RT14 Transmitter with Built-In Digital Display. Fo DEF, non-aromatic / non-halogenated organic chemicals, petroleum products / oils and grease.The FLOMEC PPS Oval Gear series provides precise volumetric flow measurement of a broad range of clean water-based products and aggressive chemicals, and is also suitable for DEF, oils, and lubricating liquids. Applications include batching, dosing, or packaging of various corrosive chemicals as a more economical alternative to a complete 316 stainless steel meter for liquids such as Diesel Exhaust Fluid (DEF) / AdBlue. NOT suitable for strong acids and oxidizers.This meter meets ISO 22241-2 Annex C, D, E, F, G, H, I, Diesel Exhaust Fluid (DEF)/AdBlue standards.Trusted by farmers and other industry professionals, the OM025PPS is the perfect flow meter for AG Chem mixing and spraying applications. Simplify and streamline your work!Flow Meter: No requirement for flow conditioning or straight pipe runs makes them ideal for compact installations with limited space.RT14 Display: Fully programmable self-powered flow rate totalizer. Four-button design with discrete and analog output.Read more about AG Chem Mixing.Check out more AG products. FeaturesLocal Display RT14, LCD backlit display, analog output and discrete output signal for connection to a variety of chart recorders, display equipment, and process control equipment. Operating temperature of -22° F to 176° F (-30° C to 80° C)Flow alarm for high, low or high/lowPPS (Ryton) Oval Gear rotors that provide highly accurate and repeatable direct volumetric readingPPS (Ryton) housing is a cost-effective alternative to a stainless-steel when chemical resistance is critical, but pressures and temperatures are lowNo requirement for flow conditioning or straight pipe runs makes them ideal for compact installations with limited spaceRecommend 100 Mesh (150 µn) filtration installed prior to meter SpecificationsAccuracy (%of reading) - Meter: ± 0.2% with optional RT14 with non-linearity correctionRepeatability - Meter: +/- 0.03%Metric Operating Fluid Temp - Min: -40°Metric Operating Fluid Temp - Max: 80°Metric Operating Fluid Temp - Units: CStd Operating Fluid Temp - Max: 176°Std Operating Fluid Temp - Min: -40°Std Operating Fluid Temp - Units: FStd Pressure Rating: 174Std Pressure Rating - Units: psiMetric Pressure Rating: 12Metric Pressure Rating - Units: barSafety Classification: Safe Area OnlyStd Flow Range - Min: 2.6Std Flow Range - Max: 40Std Flow Range - Units: GPMMetric Flow Range - Min: 10Metric Flow Range - Max: 150Metric Flow Range - Units: L/minTechnology: Oval GearLine Size: 1-inchFitting Type - Meter: NPT (Female)Housing Material - Meter: PPSRotor Material - Meter: PPS / No BearingWetted Materials - Meter: FKM|PPSWetted O-Ring/Seal Material - Meter: FKM (Viton)Powered By: AA 3.6V Lithium Thionyl Chloride Battery, External DC powered, or Loop powered (12 - 30V (dc)Field Calibration: YesApproval - Combined: CE | IP65 | NEMA 4What's in the Box: Oval Gear Transmitter with Built-In Digital Display, operating instructions, Calibration CertificateRecommended Filtration: 100 Mesh (150 µm)Output Type: 4-20 mA|Scaled Pulse|Unscaled Pulse (raw)Instrumentation Type: Transmitter with Built-in Digital DisplayMinimum Viscosity: 3Maximum Viscosity: 1,000Viscosity Units: cPAccuracy (%of reading) - Meter: ± 0.2% with optional RT14 with non-linearity correctionRepeatability - Meter: +/- 0.03%Metric Operating Fluid Temp - Min: -40°Metric Operating Fluid Temp - Max: 80°Metric Operating Fluid Temp - Units: CStd Operating Fluid Temp - Max: 176°Std Operating Fluid Temp - Min: -40°Std Operating Fluid Temp - Units: FStd Pressure Rating: 174Std Pressure Rating - Units: psiMetric Pressure Rating: 12Metric Pressure Rating - Units: barSafety Classification: Safe Area OnlyStd Flow Range - Min: 2.6Std Flow Range - Max: 40Std Flow Range - Units: GPMMetric Flow Range - Min: 10Metric Flow Range - Max: 15…
This is your item. Ready to proceed?
Add it to your RFQ basket or submit your requirement directly — ACG will respond within 24 hours with pricing, availability and delivery options.