| Materials of Construction | Aluminum Alloy ADC12 Corro-Coat PE 74-141 Polyester Powder Coat |
| Weight | 8.4 lbs (3.8 kg) |
| Display Elements | Liquid Crystal Display (LCD) |
| Cable Entry | ½ in. NPT (5); ¾ in. NPT (2) |
| Temperature Rating | -40 to 158 °F (-40 to 70 °C) |
| Input Voltage | 9 to 28 VDC, 4.5 A Maximum (including solenoid valves) |
| Pulse Output | 5 to 28 V Peak to Peak, 7500 Hz Maximum |
| Scale Pulse Output | 150 mA Sinking Capability |
| Electrical Protection | 5 A Fuse |
| Communications | RS-232: EIA-232E Standard; RS-485: SAE J1708 Standard |
| Auxiliary 1 Output | 1 A Sinking Capability |
| Auxiliary 2 Output | 150 mA Sinking Capability |
| Solenoid 1 Output | 10.2 to 27.2 VDC; 1 A Maximum |
| Solenoid 2 Output | 10.2 to 27.2 VDC; 1 A Maximum |
| Solenoid 3 Output | 10.2 to 27.2 VDC; 1 A Maximum |
| Optical Sensor | +10 to +28 VDC; 0.5 A Maximum |
| RTD Temperature Probe | 4 Wire Platinum Sensor; 100 Ω Resistance at 0 ºC; 138.5 Ω Resistance at 100 ºC |
| Remote Electronic Display | 1 A Sinking Capability |
| SKU | LCR2EGG |
| Manufacturer | Liquid Controls |
The Liquid Controls LectroCount LCR-II is a microprocessor-based electronic meter register that can be used for Weights & Measures approved custody transfer actions in mobile or fixed installations. The LCR-II can control a meter system as a stand-alone unit, or it can be used as a slave to a host contoller such as a process controller or an in-cab data management system. Features Weights & Measures custody transfer (product delivery and ticket generation) Metrological data collection Four product calibrations Multi-point and Single-point calibration Printed delivery, shift, and diagnostic tickets Delivery quantity and totalizer Security settings Two auxiliary outputs (settings include: On, Off, On During Delivery, Monitor Flow Rate, Toggle Flowrate, and Flow Direction) No-flow timer RS232/RS485 communication Electronic temperature volume compensation (ETVC) Electronic presetting by volume Electronic valve control Electronic air or vapor elimination 10-digit totalizer Two control buttons for accessing and adjusting programmable data NEMA 4X enclosure -40 to 158 °F (-40 to 70 °C) temperature range Available in Class I, Div 1 or Div 2 enclosure, Groups C & D Easy-to-use RUN, STOP, PRINT, SHIFT PRINT red rotary selector switch Hinged door for easy access to internal connections One closure connection point with Weights & Measures sealable captive fastener Compatible with most flowmeters (accepts input from PD, Amplified Turbine, Electromagnetic and Mass flowmeters) Specifications Materials of Construction: Aluminum Alloy ADC12 Corro-Coat PE 74-141 Polyester Powder Coat Weight: 8.4 lbs (3.8 kg) Display Elements: Liquid Crystal Display (LCD) Cable Entry: ½ in. NPT (5); ¾ in. NPT (2) Temperature Rating: -40 to 158 °F (-40 to 70 °C) Input Voltage: 9 to 28 VDC, 4.5 A Maximum (including solenoid valves) Pulse Output: 5 to 28 V Peak to Peak, 7500 Hz Maximum Scale Pulse Output: 150 mA Sinking Capability Electrical Protection: 5 A Fuse Communications: RS-232: EIA-232E Standard; RS-485: SAE J1708 Standard Auxiliary 1 Output: 1 A Sinking Capability Auxiliary 2 Output: 150 mA Sinking Capability Solenoid 1 Output: 10.2 to 27.2 VDC; 1 A Maximum Solenoid 2 Output: 10.2 to 27.2 VDC; 1 A Maximum Solenoid 3 Output: 10.2 to 27.2 VDC; 1 A Maximum Optical Sensor: +10 to +28 VDC; 0.5 A Maximum RTD Temperature Probe: 4 Wire Platinum Sensor; 100 Ω Resistance at 0 ºC; 138.5 Ω Resistance at 100 ºC Remote Electronic Display: 1 A Sinking Capability Downloads LectroCount LCR-II - E3657/E3658 Series Installation Guide (PDF Download)
This is your item. Ready to proceed?
Add it to your RFQ basket or submit your requirement directly — ACG will respond within 24 hours with pricing, availability and delivery options.