PART OF THE NOVA PLATFORM · KAMPALA, UGANDA · MALATYA, TURKEY · GLASGOW, SCOTLAND
NEWSON GALE Earth-Rite® II FIBC Static Grounding Protection w/ Plastic Static Dissipative Enclosure - 1 x 10⁷ Ohms FIBC7P1UA1A1E
Newson Gale

NEWSON GALE Earth-Rite® II FIBC Static Grounding Protection w/ Plastic Static Dissipative Enclosure - 1 x 10⁷ Ohms FIBC7P1UA1A1E

Part No. FIBC7P1UA1A1E Unit EA
Power Supply (AC version) 108/125V or 216/250 V AC, 50-60 Hz 12 V or 24 V DC
Power Rating 10 watt
Ambient Temperature Range -13°C to +131°C
Ingress protection Type 4X (IP 66)
Construction Carbon-Loaded GRP
Monitoring Circuit Intrinsically safe
Pricing available on request — ACG will respond within 24 hours with a full proposal.
Send requirement directly
Power Supply (AC version) 108/125V or 216/250 V AC, 50-60 Hz 12 V or 24 V DC
Power Rating 10 watt
Ambient Temperature Range -13°C to +131°C
Ingress protection Type 4X (IP 66)
Construction Carbon-Loaded GRP
Monitoring Circuit Intrinsically safe
Operational Series Ground Resistance ≤ 1 x 10⁷ or 1 x 10⁸ Ohms
Output Relay Contacts Rating 2 dry contacts; 250 V AC, 5 A, 500 VA max resistive; 30 V DC, 2 A, 60 W max resistive
Cable Entries 7 x M20 (4 x plugged)
Enclosure Material GRP with carbon loading
Terminals 2 x AWG #14 conductor capacity
Stowage Device Insulated 0.19 in. diameter pin
Clamp Cable Connection Quick Connect
Clamp Design 1 pole with single stainless steel contact
Body Stainless Steel (SS 304)
Certification Ex II 1 GD T6
Cable Blue Cen-Stat Hytrel sheath (Static dissipative, chemical & abrasion resistant)
Conductors 1 x AWG #12 steel
Length 5 meters extended, 1 meter unextended
SKU NGFIBC7P1UA1A1E

The Earth-Rite® FIBC system validates and monitors the resistance of Type C FIBC bags ensuring that the conductive elements of the bag are capable of dissipating electrostatic charges in compliance with IEC 61340-4-4 “Standard test methods for specific applications – Electrostatic classification of flexible intermediate bulk containers (FIBC)” and NFPA 77 “Recommended Practice on Static Electricity”. The Earth-Rite FIBC system can be installed and setup to ensure that operators ground the bag before filling or emptying operations are started. During the bag filling / emptying process the Earth-Rite FIBC system continuously monitors the resistance of the bag so that if it rises above the recommended level of ohms (10 meg-ohm) this dangerous situation can be indicated to operators and the process halted, either manually or via the system’s pair of NO/NC volt free contacts. This feature ensures the generation and accumulation of static charges on the bag is stopped eliminating the risk of an electrostatic spark discharge. Note: Several configurations available! Please call for more information. Features Attention Grabbing LEDs: Three green LEDs continuously pulse informing operators that the FIBC bag to be protected from static discharges is correctly grounded - When the system is not in use, or when it detects the resistance in the static dissipative loop is higher than 1 x 10⁷ or 1 x 10⁸ Ohms a red LED illuminates the indicator panel located in the static dissipative GRP indicator station Continuous Ground Loop Monitoring: Monitors the resistance of the static dissipative loop through the FIBC bag back to the Earth-Rite FIBC via the plant earth grounding point - If the system detects that resistance in the loop is higher than 1 x 10⁷ohms, it engages a pair of output contacts Two Volt Free Output Contacts: The primary contact can interlock with electro-mechanical devices or PLC systems to shutdown the flow of product - The secondary contact can interface with attention grabbing audible alarms or strobe lights to provide an extra degree of safety over the hazard Easy Installation: Simple to mount enclosures complemented by straightforward cabling and PCB system wiring - Flexible hazardous area enclosure location options with separate IS monitoring / indicator and Power supply PCBs. Power supply PCB can run off both 240 V and 110 V mains / line supply and 24 V / 12 V DC voltage supply Specifications Power Supply & Monitoring Unit Power Supply (AC version): 108/125V or 216/250 V AC, 50-60 Hz 12 V or 24 V DC Power Rating: 10 watt Ambient Temperature Range: -13°C to +131°C Ingress protection: Type 4X (IP 66) Construction: Carbon-Loaded GRP Monitoring Circuit: Intrinsically safe Operational Series Ground Resistance: ≤ 1 x 10⁷ or 1 x 10⁸ Ohms Output Relay Contacts Rating: 2 dry contacts; 250 V AC, 5 A, 500 VA max resistive; 30 V DC, 2 A, 60 W max resistive Cable Entries: 7 x M20 (4 x plugged) Junction Box/Stowage Point Enclosure Material: GRP with carbon loading Terminals: 2 x AWG #14 conductor capacity Stowage Device: Insulated 0.19 in. diameter pin Cable Entries: 1 x M20 Clamp Cable Connection: Quick Connect Grounding Clamp Clamp Design: 1 pole with single stainless steel contact Body: Stainless Steel (SS 304) Certification: Ex II 1 GD T6 Spiral Cable Cable: Blue Cen-Stat Hytrel sheath (Static dissipative, chemical & abrasion resistant) Cable: Orange Cen-Stat Hytrel sheath (Static dissipative, chemical & abrasion resistant) Conductors: 1 x AWG #12 steel Length: 5 meters extended, 1 meter unextended Downloads FIBC Static Grounding Protection Datasheet (PDF Download) FIBC Static Grounding Protection Application Spotlight (PDF Download) Specification Sheet (PDF Download)

This is your item. Ready to proceed?

Add it to your RFQ basket or submit your requirement directly — ACG will respond within 24 hours with pricing, availability and delivery options.

RFQ Basket

Your RFQ basket is empty

Browse the catalogue and add items to build your requirement list Browse catalogue
Search