PART OF THE NOVA PLATFORM · KAMPALA, UGANDA · MALATYA, TURKEY · GLASGOW, SCOTLAND
DWYER Series HHT Hazardous Area Humidity/Temperature Transmitter, Intrinsically Safe DWYR8X
Dwyer

DWYER Series HHT Hazardous Area Humidity/Temperature Transmitter, Intrinsically Safe DWYR8X

Part No. DWYR8X Unit EA
Relative Humidity Range 0 to 100% RH.
Temperature Range -40 to 140°F (-40 to 60°C).
Accuracy ±2% 10 to 90% RH, ±0.9°F at 72°F (±0.3°C at 25°C).
Hysteresis ±1%.
Repeatability ±0.1% typical.
Temperature Limits -40 to 140°F (-40 to 60°C).
Pricing available on request — ACG will respond within 24 hours with a full proposal.
Send requirement directly
Relative Humidity Range 0 to 100% RH.
Temperature Range -40 to 140°F (-40 to 60°C).
Accuracy ±2% 10 to 90% RH, ±0.9°F at 72°F (±0.3°C at 25°C).
Hysteresis ±1%.
Repeatability ±0.1% typical.
Temperature Limits -40 to 140°F (-40 to 60°C).
Storage Temperature -40 to 176°F (-40 to 80°C).
Compensated Temperature -40 to 140°F (-40 to 60°C).
Power Requirements For intrinsically safe models HHT-IX, 9.5 to 28 VDC. For explosion-proof models HHT-EX, 16.5 to 28 VDC.
Output Signal 4 to 20 mA
Response Time 15 electrical
Connections Screw terminal block.
Conduit Connection 1/2" female
Updrift <1% RH/year.
RH Sensor Capacitance polymer.
Temperature Sensor Solid state band gap.
Housing Material Aluminum.
Display Optional 2 line alpha numeric, 8 characters/line.
Display Resolution RH: 0.1%;
Temperature 0.1°F (0.1°C).Weight:2 lb 8 oz (1134 g).

The&nbsp;Series HHT Hazardous Area Humidity/Temperature Transmitter&nbsp;takes accurate measurements in the harshest of environments. The explosion-proof model is offered with 4 to 20 mA output for humidity only. The intrinsically safe version is offered with 4 to 20 mA output for humidity and temperature, and do require an intrinsically safe barrier to meet hazardous area approvals. Applications: Process Monitoring, Offshore HVAC Monitoring, Dust &amp; Grain Handling. Features FM approved explosion-proof and intrinsically safe models Temperature and relative humidity output models Some models include Integral LCD option. Specifications Relative Humidity Range: 0 to 100% RH. Temperature Range:-40 to 140&deg;F (-40 to 60&deg;C). Accuracy:&plusmn;2% 10 to 90% RH, &plusmn;0.9&deg;F at 72&deg;F (&plusmn;0.3&deg;C at 25&deg;C). Hysteresis: &plusmn;1%. Repeatability: &plusmn;0.1% typical. Temperature Limits:-40 to 140&deg;F (-40 to 60&deg;C). Storage Temperature:-40 to 176&deg;F (-40 to 80&deg;C). Compensated Temperature:-40 to 140&deg;F (-40 to 60&deg;C). Power Requirements: For intrinsically safe models HHT-IX, 9.5 to 28 VDC. For explosion-proof models HHT-EX, 16.5 to 28 VDC. Output Signal: 4 to 20 mA 2 channels for humidity/temperature models (loop power on RH). Response Time: 15 electrical Connections: Screw terminal block. Conduit Connection: 1/2" female Updrift:&lt;1% RH/year. RH Sensor: Capacitance polymer. Temperature Sensor: Solid state band gap. Housing Material: Aluminum. Display: Optional 2 line alpha numeric, 8 characters/line. Temperature display is &deg;F/&deg;C selectable. Display Resolution: RH: 0.1%; Temperature: 0.1&deg;F (0.1&deg;C).Weight:2 lb 8 oz (1134 g). Enclosure Ratingen 4X (IP66). Models HHT-EX: FM Explosion-proof, Class I Div. 1 Group B, C, D, Class II Div. 1 Group E, F, G, Class III Div. 1 Models HHT-IX: FM Intrinsically Safe, Class I Div. 1 Group A, B, C, D, Class II Div. 1 Group E, F, G, Class III Div. 1 T4. Agency Approvals: FM, CE. Downloads Product Manual (PDF Download)

This is your item. Ready to proceed?

Add it to your RFQ basket or submit your requirement directly — ACG will respond within 24 hours with pricing, availability and delivery options.

RFQ Basket

Your RFQ basket is empty

Browse the catalogue and add items to build your requirement list Browse catalogue