PART OF THE NOVA PLATFORM · KAMPALA, UGANDA · MALATYA, TURKEY · GLASGOW, SCOTLAND
FLOWLINE DeltaSpan LD30 Submersible Pressure Level Transmitter, 34 ft. Range LD30-S201
Flowline

FLOWLINE DeltaSpan LD30 Submersible Pressure Level Transmitter, 34 ft. Range LD30-S201

Part No. LD30-S201 Unit EA
Range -S0_1: 0 to 5 psi (0.34 bar) or 0 to 11.55 ft. (0 to 3.5m) wc; -S2_1: 0 to 15 psi (1 bar) or 0 to 34.65 ft. (0 to 10.6m) wc
Accuracy ± 0.25% of full scale
Configuration None, fixed span
Supply voltage 11-28 VDC
Loop resistance 900 Ohms max @ 30 VDC
Signal output 4-20 mA, two-wire
Pricing available on request — ACG will respond within 24 hours with a full proposal.
Send requirement directly
Range -S0_1: 0 to 5 psi (0.34 bar) or 0 to 11.55 ft. (0 to 3.5m) wc; -S2_1: 0 to 15 psi (1 bar) or 0 to 34.65 ft. (0 to 10.6m) wc
Accuracy ± 0.25% of full scale
Configuration None, fixed span
Supply voltage 11-28 VDC
Loop resistance 900 Ohms max @ 30 VDC
Signal output 4-20 mA, two-wire
Process temp. F: 14° to 176°; C: -10° to 80°
Temp. comp. Automatic
Burst pressure 2 x full scale
Response time 50ms
Process mount 1/4 in. NPT
Sensor material 316 stainless steel
Enclosure rating NEMA 4X (IP65)
Termination -S_01: Cable; -S_11: M12 connector (male)
Cable type -S_01: 2-conductor, shielded
Cable material -S_01: PUR (polyurethane)
Cable length -S_01: 9 ft. (2.7m)
Classification General purpose
Compliance CE, RoHS
SKU FLWLD30S201

DescriptionThe LD30 general purpose external mount pressure level transmitter provides continuous liquid level measurement up to 34.65’ (10.5m) of water column with a 4-20 mA signal output. Offered in two level measurement ranges and termination types, select the -S_01 model for cable termination or the -S_11 model for M12 connector termination. The LD30 pressure level sensor is well suited for clean liquids compatible with 316 SS such as process water and diluted chemicals. FeaturesRugged 316 SS transducer body and threaded fitting mount Offered in cable or connector termination for flexible installation Integral surge protection for lightning strikes or power surges Automatic temperature compensation for reliable measurement SpecificationsRange: -S0_1: 0 to 5 psi (0.34 bar) or 0 to 11.55 ft. (0 to 3.5m) wc; -S2_1: 0 to 15 psi (1 bar) or 0 to 34.65 ft. (0 to 10.6m) wc Accuracy: ± 0.25% of full scale Configuration: None, fixed span Supply voltage: 11-28 VDC Loop resistance: 900 Ohms max @ 30 VDC Signal output: 4-20 mA, two-wire Process temp.: F: 14° to 176°; C: -10° to 80° Temp. comp.: Automatic Burst pressure: 2 x full scale Response time: 50ms Process mount: 1/4 in. NPT Sensor material: 316 stainless steel Enclosure rating: NEMA 4X (IP65) Termination: -S_01: Cable; -S_11: M12 connector (male) Cable type: -S_01: 2-conductor, shielded Cable material: -S_01: PUR (polyurethane) Cable length: -S_01: 9 ft. (2.7m) Classification: General purpose Compliance: CE, RoHS

This is your item. Ready to proceed?

Add it to your RFQ basket or submit your requirement directly — ACG will respond within 24 hours with pricing, availability and delivery options.

RFQ Basket

Your RFQ basket is empty

Browse the catalogue and add items to build your requirement list Browse catalogue
Search