- Miniature Circuit Breakers
Page 55 of 64
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F23232 |
Number of Poles |
: |
2P |
Current Rating |
: |
32A |
Tripping Characteristics |
: |
Type D |
Rated AC Voltage |
: |
440V |
Rated DC Voltage |
: |
125V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
36mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F23232 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F10432 |
Number of Poles |
: |
4P |
Current Rating |
: |
32A |
Tripping Characteristics |
: |
Type B |
Breaking Capacity at Maximum Voltage Rating |
: |
40 kA |
Range |
: |
Multi 9 |
Series |
: |
C60N |
Circuit Breaker Type |
: |
MCB |
Length |
: |
81mm |
Width |
: |
72mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F22203 |
Number of Poles |
: |
2P |
Current Rating |
: |
3A |
Tripping Characteristics |
: |
Type C |
Rated AC Voltage |
: |
440V |
Rated DC Voltage |
: |
125V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
36mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F22203 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F21240 |
Number of Poles |
: |
2P |
Current Rating |
: |
40A |
Tripping Characteristics |
: |
Type B |
Rated AC Voltage |
: |
440V |
Rated DC Voltage |
: |
125V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
36mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F21240 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F22240 |
Number of Poles |
: |
2P |
Current Rating |
: |
40A |
Tripping Characteristics |
: |
Type C |
Rated AC Voltage |
: |
440V |
Rated DC Voltage |
: |
125V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
36mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F22240 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F10463 |
Number of Poles |
: |
4P |
Current Rating |
: |
63A |
Tripping Characteristics |
: |
Type B |
Breaking Capacity at Maximum Voltage Rating |
: |
40 kA |
Range |
: |
Multi 9 |
Series |
: |
C60N |
Circuit Breaker Type |
: |
MCB |
Length |
: |
81mm |
Width |
: |
72mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F22204 |
Number of Poles |
: |
2P |
Current Rating |
: |
4A |
Tripping Characteristics |
: |
Type C |
Rated AC Voltage |
: |
440V |
Rated DC Voltage |
: |
125V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
36mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F22204 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F21110 |
Number of Poles |
: |
1P |
Current Rating |
: |
10A |
Tripping Characteristics |
: |
Type B |
Rated AC Voltage |
: |
415V |
Rated DC Voltage |
: |
60V |
Breaking Capacity at Maximum Voltage Rating |
: |
20 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
18mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F21110 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F23204 |
Number of Poles |
: |
2P |
Current Rating |
: |
4A |
Tripping Characteristics |
: |
Type D |
Rated AC Voltage |
: |
440V |
Rated DC Voltage |
: |
125V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
36mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F23204 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F22113 |
Number of Poles |
: |
1P |
Current Rating |
: |
13A |
Tripping Characteristics |
: |
Type C |
Rated AC Voltage |
: |
415V |
Rated DC Voltage |
: |
60V |
Breaking Capacity at Maximum Voltage Rating |
: |
20 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
18mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F22113 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
Terminal Contact Type |
: |
Tunnel Terminal |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F23205 |
Number of Poles |
: |
2P |
Current Rating |
: |
5A |
Tripping Characteristics |
: |
Type D |
Rated AC Voltage |
: |
440V |
Rated DC Voltage |
: |
125V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
36mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F23205 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F23113 |
Number of Poles |
: |
1P |
Current Rating |
: |
13A |
Tripping Characteristics |
: |
Type D |
Rated AC Voltage |
: |
415V |
Rated DC Voltage |
: |
60V |
Breaking Capacity at Maximum Voltage Rating |
: |
20 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
18mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F23113 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F22263 |
Number of Poles |
: |
2P |
Current Rating |
: |
63A |
Tripping Characteristics |
: |
Type C |
Rated AC Voltage |
: |
440V |
Rated DC Voltage |
: |
125V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
36mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F22263 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F23316 |
Number of Poles |
: |
3P |
Current Rating |
: |
16A |
Tripping Characteristics |
: |
Type D |
Rated AC Voltage |
: |
440V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
54mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F23316 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
Application |
: |
Distribution |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F21320 |
Number of Poles |
: |
3P |
Current Rating |
: |
20A |
Tripping Characteristics |
: |
Type B |
Rated AC Voltage |
: |
440V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
54mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F21320 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F22320 |
Number of Poles |
: |
3P |
Current Rating |
: |
20A |
Tripping Characteristics |
: |
Type C |
Rated AC Voltage |
: |
440V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
54mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F22320 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
Application |
: |
Distribution |
Terminal Contact Type |
: |
Screw |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F23320 |
Number of Poles |
: |
3P |
Current Rating |
: |
20A |
Tripping Characteristics |
: |
Type D |
Rated AC Voltage |
: |
440V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
54mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F23320 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F23325 |
Number of Poles |
: |
3P |
Current Rating |
: |
25A |
Tripping Characteristics |
: |
Type D |
Rated AC Voltage |
: |
440V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
54mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F23325 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F23425 |
Number of Poles |
: |
3P |
Current Rating |
: |
25A |
Tripping Characteristics |
: |
Type D |
Rated AC Voltage |
: |
440V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
54mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F23425 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F21302 |
Number of Poles |
: |
3P |
Current Rating |
: |
2A |
Tripping Characteristics |
: |
Type B |
Rated AC Voltage |
: |
440V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
54mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F21302 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F22302 |
Number of Poles |
: |
3P |
Current Rating |
: |
2A |
Tripping Characteristics |
: |
Type C |
Rated AC Voltage |
: |
440V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
54mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F22302 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F23302 |
Number of Poles |
: |
3P |
Current Rating |
: |
2A |
Tripping Characteristics |
: |
Type D |
Rated AC Voltage |
: |
440V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
54mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F23302 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F21332 |
Number of Poles |
: |
3P |
Current Rating |
: |
32A |
Tripping Characteristics |
: |
Type B |
Rated AC Voltage |
: |
440V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
54mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F21332 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F22332 |
Number of Poles |
: |
3P |
Current Rating |
: |
32A |
Tripping Characteristics |
: |
Type C |
Rated AC Voltage |
: |
440V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
54mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F22332 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F23332 |
Number of Poles |
: |
3P |
Current Rating |
: |
32A |
Tripping Characteristics |
: |
Type D |
Rated AC Voltage |
: |
440V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
54mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F23332 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F21340 |
Number of Poles |
: |
3P |
Current Rating |
: |
40A |
Tripping Characteristics |
: |
Type B |
Rated AC Voltage |
: |
440V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
54mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F21340 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F22340 |
Number of Poles |
: |
3P |
Current Rating |
: |
40A |
Tripping Characteristics |
: |
Type C |
Rated AC Voltage |
: |
440V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
54mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F22340 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
Application |
: |
Distribution |
Terminal Contact Type |
: |
Screw |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F21350 |
Number of Poles |
: |
3P |
Current Rating |
: |
50A |
Tripping Characteristics |
: |
Type B |
Rated AC Voltage |
: |
440V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
54mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F21350 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F22363 |
Number of Poles |
: |
3P |
Current Rating |
: |
63A |
Tripping Characteristics |
: |
Type C |
Rated AC Voltage |
: |
440V |
Breaking Capacity at Maximum Voltage Rating |
: |
10 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
MCB |
Length |
: |
81mm |
Width |
: |
54mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
C60 |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F21306 |
Number of Poles |
: |
3P |
Current Rating |
: |
6A |
Tripping Characteristics |
: |
Type B |
Rated AC Voltage |
: |
440V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
54mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F21306 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F22306 |
Number of Poles |
: |
3P |
Current Rating |
: |
6A |
Tripping Characteristics |
: |
Type C |
Rated AC Voltage |
: |
440V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
54mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F22306 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F23306 |
Number of Poles |
: |
3P |
Current Rating |
: |
6A |
Tripping Characteristics |
: |
Type D |
Rated AC Voltage |
: |
440V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
54mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F23306 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F22308 |
Number of Poles |
: |
3P |
Current Rating |
: |
8A |
Tripping Characteristics |
: |
Type C |
Rated AC Voltage |
: |
440V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
54mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F22308 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F23308 |
Number of Poles |
: |
3P |
Current Rating |
: |
8A |
Tripping Characteristics |
: |
Type D |
Breaking Capacity at Maximum Voltage Rating |
: |
10 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
MCB |
Length |
: |
81mm |
Width |
: |
54mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F21410 |
Number of Poles |
: |
4P |
Current Rating |
: |
10A |
Tripping Characteristics |
: |
Type B |
Rated AC Voltage |
: |
440V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
72mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F21410 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F22425 |
Number of Poles |
: |
4P |
Current Rating |
: |
25A |
Tripping Characteristics |
: |
Type C |
Rated AC Voltage |
: |
440V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
72mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F22425 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F21420 |
Number of Poles |
: |
4P |
Current Rating |
: |
20A |
Tripping Characteristics |
: |
Type B |
Rated AC Voltage |
: |
440V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
72mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F21420 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F23420 |
Number of Poles |
: |
4P |
Current Rating |
: |
20A |
Tripping Characteristics |
: |
Type D |
Rated AC Voltage |
: |
440V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
72mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F23420 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F21432 |
Number of Poles |
: |
4P |
Current Rating |
: |
32A |
Tripping Characteristics |
: |
Type B |
Rated AC Voltage |
: |
440V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
72mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F21432 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|
Brand |
: |
Schneider Electric |
MFR # |
: |
M9F21440 |
Number of Poles |
: |
4P |
Current Rating |
: |
40A |
Tripping Characteristics |
: |
Type B |
Rated AC Voltage |
: |
440V |
Breaking Capacity at Maximum Voltage Rating |
: |
15 kA |
Range |
: |
Multi 9 |
Series |
: |
C60SP |
Circuit Breaker Type |
: |
Residential MCB |
Length |
: |
81mm |
Width |
: |
72mm |
Mounting Style |
: |
DIN Rail Mount |
Depth |
: |
72mm |
Model Number |
: |
M9F21440 |
Reset Actuator Type |
: |
Toggle Switch |
Tripping Mechanism |
: |
Thermal-Magnetic |
|