- Power Cable
Page 7 of 18
Brand |
: |
RS PRO |
MFR # |
: |
811-4368 |
Cross Sectional Area |
: |
0.75 mm² |
Number of Cores |
: |
2 |
Sheath Colour |
: |
Grey |
Length |
: |
100m |
Cable Type |
: |
2192Y |
Current Rating |
: |
6 A |
Outer Diameter |
: |
3.2 x 5.2 → 3.8 x 6.3mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V |
European Harmonised Code |
: |
H03VVH2-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
22 |
Size of Strands |
: |
0.2 mm |
Conductor Resistance |
: |
26 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-50°C |
Standards Met |
: |
BS EN 50525 |
Insulation material |
: |
PVC |
Core Strands |
: |
22/0.2 mm |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
18 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
491-932 |
Cross Sectional Area |
: |
1.5 mm² |
Number of Cores |
: |
2 |
Sheath Colour |
: |
Black |
Length |
: |
100m |
Cable Type |
: |
3182Y |
Current Rating |
: |
15 A |
Outer Diameter |
: |
8.6mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
30 |
Size of Strands |
: |
0.25 mm |
Conductor Resistance |
: |
13.3 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-15°C |
Standards Met |
: |
BS EN 50525 |
Insulation material |
: |
PVC |
Core Strands |
: |
30/0.25 mm |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
15 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
902-8350 |
Cross Sectional Area |
: |
2.5 mm² |
Number of Cores |
: |
5 |
Sheath Colour |
: |
Grey |
Length |
: |
100m |
Cable Type |
: |
NYM-J |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
11.5 → 14mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V, 500 V |
Conductor Strand Type |
: |
Solid |
Size of Strands |
: |
1.75 mm |
Conductor Resistance |
: |
7.41 Ω/km |
Minimum Operating Temperature |
: |
-5°C |
Standards Met |
: |
HD 21.4 S2, IEC 60288, IEC 60332-1 |
Insulation material |
: |
PVC |
Fire Behaviour |
: |
Flame Retardant |
Maximum Operating Temperature |
: |
+70°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
902-8335 |
Cross Sectional Area |
: |
1.5 mm² |
Number of Cores |
: |
4 |
Sheath Colour |
: |
Grey |
Length |
: |
50m |
Cable Type |
: |
NYM-J |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
11.5mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
500 V |
Conductor Strand Type |
: |
Solid |
Size of Strands |
: |
1.365 mm |
Conductor Resistance |
: |
12.1 Ω/km |
Minimum Operating Temperature |
: |
-5°C |
Standards Met |
: |
HD 21.4 S2, IEC 60228 Class1, IEC 60332-1 |
Insulation material |
: |
PVC |
Fire Behaviour |
: |
Flame Retardant |
Maximum Operating Temperature |
: |
+70°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
773-9020 |
Cross Sectional Area |
: |
1 mm² |
Number of Cores |
: |
2 |
Sheath Colour |
: |
Black |
Length |
: |
100m |
Current Rating |
: |
17 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
8.3mm |
Sheath Material |
: |
CPE |
Voltage Rating |
: |
450 V, 750 V |
European Harmonised Code |
: |
H07RN-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
32 |
Size of Strands |
: |
0.19 mm |
Conductor Resistance |
: |
19.5 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-25°C |
Standards Met |
: |
VDE 0285-525-2-21 |
Insulation material |
: |
EPR |
Core Strands |
: |
32/0.19 mm |
Fire Behaviour |
: |
Flame Retardant |
Maximum Operating Temperature |
: |
+60°C |
American Wire Gauge |
: |
17 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
491-885 |
Cross Sectional Area |
: |
0.75 mm² |
Number of Cores |
: |
3 |
Sheath Colour |
: |
White |
Length |
: |
50m |
Cable Type |
: |
2183Y |
Current Rating |
: |
6 A |
Outer Diameter |
: |
6.7mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V |
European Harmonised Code |
: |
H03VV-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
24 |
Size of Strands |
: |
0.2 mm |
Conductor Resistance |
: |
26 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-15°C |
Standards Met |
: |
BS EN 50525 |
Insulation material |
: |
PVC |
Core Strands |
: |
24/0.2 mm |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
18 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
491-847 |
Cross Sectional Area |
: |
0.5 mm² |
Number of Cores |
: |
3 |
Sheath Colour |
: |
Grey |
Length |
: |
100m |
Cable Type |
: |
2183Y |
Current Rating |
: |
3 A |
Outer Diameter |
: |
6.3mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V |
European Harmonised Code |
: |
H03VV-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
16 |
Size of Strands |
: |
0.2 mm |
Conductor Resistance |
: |
39 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-15°C |
Standards Met |
: |
BS EN 50525 |
Insulation material |
: |
PVC |
Core Strands |
: |
16/0.2 mm |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
20 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
492-052 |
Cross Sectional Area |
: |
1 mm² |
Number of Cores |
: |
2 |
Sheath Colour |
: |
Grey |
Length |
: |
100m |
Cable Type |
: |
3182Y |
Current Rating |
: |
10 A |
Outer Diameter |
: |
7.5mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
32 |
Size of Strands |
: |
0.2 mm |
Conductor Resistance |
: |
19.5 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-15°C |
Standards Met |
: |
BS EN 50525 |
Insulation material |
: |
PVC |
Core Strands |
: |
32/0.2 mm |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
17 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
836-0707 |
Cross Sectional Area |
: |
1.5 mm² |
Number of Cores |
: |
4 |
Length |
: |
100m |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
10.2 → 13.1mm |
Sheath Material |
: |
Cross-Linked Compound, Type EM 8 to EN 50363-6 |
Voltage Rating |
: |
750 V |
European Harmonised Code |
: |
H07ZZ-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
27 |
Size of Strands |
: |
0.25 mm |
Conductor Resistance |
: |
13.3 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-5°C |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
Cross Linked |
Core Strands |
: |
27/0.25 mm |
Maximum Operating Temperature |
: |
+90°C |
American Wire Gauge |
: |
15 AWG |
Cable Shape |
: |
Round |
|
Brand |
: |
RS PRO |
MFR # |
: |
491-784 |
Cross Sectional Area |
: |
0.75 mm² |
Number of Cores |
: |
3 |
Sheath Colour |
: |
Grey |
Length |
: |
100m |
Cable Type |
: |
3183Y |
Current Rating |
: |
6 A |
Outer Diameter |
: |
7.6mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
24 |
Size of Strands |
: |
0.2 mm |
Conductor Resistance |
: |
26 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-15°C |
Standards Met |
: |
BS EN 50525 |
Insulation material |
: |
PVC |
Core Strands |
: |
24/0.2 mm |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
18 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
811-4387 |
Cross Sectional Area |
: |
2.5 mm² |
Number of Cores |
: |
3 |
Sheath Colour |
: |
Grey |
Length |
: |
100m |
Cable Type |
: |
3183Y |
Current Rating |
: |
20 A |
Outer Diameter |
: |
11.4mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V, 500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Solid |
Number of Strands |
: |
50 |
Size of Strands |
: |
0.25 mm |
Conductor Resistance |
: |
7.98 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-15°C |
Standards Met |
: |
BS EN 50525 |
Insulation material |
: |
PVC Type TI1 to BS7655 |
Core Strands |
: |
50/0.25 mm |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
13 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
836-0748 |
Cross Sectional Area |
: |
2.5 mm² |
Number of Cores |
: |
3 |
Sheath Colour |
: |
White |
Length |
: |
100m |
Cable Type |
: |
Fire Performance |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
9.2 → 11.4mm |
Voltage Rating |
: |
500 V |
European Harmonised Code |
: |
H05Z1Z1-F |
Number of Strands |
: |
45 |
Size of Strands |
: |
0.25 mm |
Conductor Resistance |
: |
7.98 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-5°C |
Standards Met |
: |
BS EN 50525 |
Insulation material |
: |
Thermoplastic |
Fire Behaviour |
: |
Flame Retardant |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
13 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
821-3254 |
Cross Sectional Area |
: |
6 mm² |
Number of Cores |
: |
5 |
Sheath Colour |
: |
Black |
Length |
: |
50m |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
19.1mm |
Sheath Material |
: |
CPE |
Voltage Rating |
: |
450/750 V ac |
European Harmonised Code |
: |
H07RN-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
84 |
Size of Strands |
: |
0.3 mm |
Conductor Resistance |
: |
3.3 Ω/km |
Conductor Material |
: |
Bare Copper |
Standards Met |
: |
VDE 0285-525-2-21 |
Insulation material |
: |
EPR |
Core Strands |
: |
84/0.29 mm |
Maximum Operating Temperature |
: |
+60°C |
American Wire Gauge |
: |
9 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
841-2252 |
Cross Sectional Area |
: |
0.75 mm² |
Number of Cores |
: |
2 |
Length |
: |
100m |
Cable Type |
: |
2182Y |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
5.1mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V |
European Harmonised Code |
: |
H03VV-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
22 |
Size of Strands |
: |
0.2 mm |
Conductor Resistance |
: |
26 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-50°C |
Standards Met |
: |
IEC 60227-5, RoHS Compliant, TS 9760 HD 21.5.S3, VDE 0281-5 |
Insulation material |
: |
PVC |
Core Strands |
: |
22/0.2 mm |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
18 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
775-5849 |
Cross Sectional Area |
: |
0.5 mm² |
Number of Cores |
: |
3 |
Sheath Colour |
: |
Grey |
Length |
: |
100m |
Cable Type |
: |
2183Y |
Current Rating |
: |
3 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
5.39mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V |
European Harmonised Code |
: |
H03VV-F |
Conductor Strand Type |
: |
Stranded |
Conductor Resistance |
: |
39 Ω/km |
Conductor Material |
: |
Copper |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
PVC |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
20 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
492-024 |
Cross Sectional Area |
: |
0.75 mm² |
Number of Cores |
: |
5 |
Sheath Colour |
: |
Black |
Length |
: |
100m |
Cable Type |
: |
3185Y |
Current Rating |
: |
6 A |
Outer Diameter |
: |
8mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
24 |
Size of Strands |
: |
0.2 mm |
Conductor Resistance |
: |
26 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-15°C |
Standards Met |
: |
BS EN 50525 |
Insulation material |
: |
PVC |
Core Strands |
: |
24/0.2 mm |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
18 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
863-4014 |
Cross Sectional Area |
: |
1.5 mm² |
Number of Cores |
: |
3 |
Sheath Colour |
: |
Black |
Length |
: |
100m |
Cable Type |
: |
TRS |
Current Rating |
: |
16 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
8.5 → 8.9mm |
Sheath Material |
: |
CPE |
Voltage Rating |
: |
300 V, 500 V |
European Harmonised Code |
: |
H05RR-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
30 |
Size of Strands |
: |
0.24 mm |
Conductor Resistance |
: |
13.3 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-25°C |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
EPDM |
Core Strands |
: |
30/0.24 mm |
Maximum Operating Temperature |
: |
+60°C |
American Wire Gauge |
: |
15 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
902-8369 |
Cross Sectional Area |
: |
1.5 mm² |
Number of Cores |
: |
6 |
Sheath Colour |
: |
Grey |
Length |
: |
50m |
Cable Type |
: |
NYM-J |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
11 → 13mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V, 500 V |
Conductor Strand Type |
: |
Solid |
Conductor Resistance |
: |
12.1 Ω/km |
Minimum Operating Temperature |
: |
-5°C |
Standards Met |
: |
HD 21.4 S2, IEC 60288, IEC 60332-1 |
Insulation material |
: |
PVC |
Fire Behaviour |
: |
Flame Retardant |
Maximum Operating Temperature |
: |
+70°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
902-8300 |
Cross Sectional Area |
: |
4 mm² |
Number of Cores |
: |
3 |
Sheath Colour |
: |
Black |
Length |
: |
50m |
Cable Type |
: |
NYY-J |
CPR Certification |
: |
Eca |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
1 kV, 600 V |
Conductor Strand Type |
: |
Solid |
Size of Strands |
: |
2.19 mm |
Conductor Resistance |
: |
4.61 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-5°C |
Standards Met |
: |
EN 50265-2-1, IEC 60228 Class 1, IEC 60332-1, IEC 60502-1, RoHS Compliant |
Insulation material |
: |
PVC |
Fire Behaviour |
: |
Flame Retardant |
Maximum Operating Temperature |
: |
+70°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
836-0713 |
Cross Sectional Area |
: |
0.75 mm² |
Number of Cores |
: |
2 |
Sheath Colour |
: |
White |
Length |
: |
100m |
Cable Type |
: |
Fire Performance |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
5.7 → 7.2mm |
Voltage Rating |
: |
500 V |
European Harmonised Code |
: |
H05Z1Z1-F |
Number of Strands |
: |
22 |
Size of Strands |
: |
0.2 mm |
Conductor Resistance |
: |
26 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-5°C |
Standards Met |
: |
BS EN 50525 |
Insulation material |
: |
Thermoplastic |
Fire Behaviour |
: |
Flame Retardant |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
18 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
491-796 |
Cross Sectional Area |
: |
1 mm² |
Number of Cores |
: |
3 |
Sheath Colour |
: |
Orange |
Length |
: |
100m |
Cable Type |
: |
3183Y |
Current Rating |
: |
10 A |
Outer Diameter |
: |
7.1mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
32 |
Size of Strands |
: |
0.2 mm |
Conductor Resistance |
: |
19.5 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-15°C |
Standards Met |
: |
BS EN 50525 |
Insulation material |
: |
PVC |
Core Strands |
: |
32/0.2 mm |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
17 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
902-8344 |
Cross Sectional Area |
: |
4 mm² |
Number of Cores |
: |
4 |
Sheath Colour |
: |
Grey |
Length |
: |
100m |
Cable Type |
: |
NYM-J |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
12 → 14.5mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V, 500 V |
Conductor Strand Type |
: |
Solid |
Size of Strands |
: |
2.19 mm |
Conductor Resistance |
: |
4.61 Ω/km |
Minimum Operating Temperature |
: |
-5°C |
Standards Met |
: |
HD 21.4 S2, IEC 60288, IEC 60332-1 |
Insulation material |
: |
PVC |
Fire Behaviour |
: |
Flame Retardant |
Maximum Operating Temperature |
: |
+70°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
491-920 |
Cross Sectional Area |
: |
2.5 mm² |
Number of Cores |
: |
2 |
Sheath Colour |
: |
Orange |
Length |
: |
50m |
Cable Type |
: |
3182Y |
Current Rating |
: |
20 A |
Outer Diameter |
: |
10.6mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
48 |
Size of Strands |
: |
0.25 mm |
Conductor Resistance |
: |
7.98 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-15°C |
Standards Met |
: |
BS EN 50525 |
Insulation material |
: |
PVC |
Core Strands |
: |
48/0.25 mm |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
13 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
775-6182 |
Cross Sectional Area |
: |
1.5 mm² |
Number of Cores |
: |
5 |
Sheath Colour |
: |
Black |
Length |
: |
100m |
Cable Type |
: |
3185Y |
Current Rating |
: |
16 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
10.1mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V, 500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Conductor Resistance |
: |
13.3 Ω/km |
Conductor Material |
: |
Copper |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
PVC |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
15 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
902-8357 |
Cross Sectional Area |
: |
4 mm² |
Number of Cores |
: |
5 |
Sheath Colour |
: |
Grey |
Length |
: |
100m |
Cable Type |
: |
NYM-J |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
13.5 → 16mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V, 500 V |
Conductor Strand Type |
: |
Solid |
Size of Strands |
: |
2.19 mm |
Conductor Resistance |
: |
4.61 Ω/km |
Minimum Operating Temperature |
: |
-5°C |
Standards Met |
: |
HD 21.4 S2, IEC 60288, IEC 60332-1 |
Insulation material |
: |
PVC |
Fire Behaviour |
: |
Flame Retardant |
Maximum Operating Temperature |
: |
+70°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
836-0704 |
Cross Sectional Area |
: |
2.5 mm² |
Number of Cores |
: |
3 |
Length |
: |
100m |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
10.9 → 14mm |
Sheath Material |
: |
Cross-Linked Compound, Type EM 8 to EN 50363-6 |
Voltage Rating |
: |
750 V |
European Harmonised Code |
: |
H07ZZ-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
45 |
Size of Strands |
: |
0.25 mm |
Conductor Resistance |
: |
7.98 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-5°C |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
Cross Linked |
Core Strands |
: |
45/0.25 mm |
Maximum Operating Temperature |
: |
+90°C |
American Wire Gauge |
: |
13 AWG |
Cable Shape |
: |
Round |
|
Brand |
: |
RS PRO |
MFR # |
: |
902-8347 |
Cross Sectional Area |
: |
1.5 mm² |
Number of Cores |
: |
5 |
Sheath Colour |
: |
Grey |
Length |
: |
50m |
Cable Type |
: |
NYM-J |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
12mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
500 V |
Conductor Strand Type |
: |
Solid |
Size of Strands |
: |
1.365 mm |
Conductor Resistance |
: |
12.1 Ω/km |
Minimum Operating Temperature |
: |
-5°C |
Standards Met |
: |
HD 21.4 S2, IEC 60228 Class1, IEC 60332-1 |
Insulation material |
: |
PVC |
Fire Behaviour |
: |
Flame Retardant |
Maximum Operating Temperature |
: |
+70°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
775-5842 |
Cross Sectional Area |
: |
0.75 mm² |
Number of Cores |
: |
2 |
Sheath Colour |
: |
White |
Length |
: |
100m |
Cable Type |
: |
2182Y |
Current Rating |
: |
6 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
5.4mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V |
European Harmonised Code |
: |
H03VV-F |
Conductor Strand Type |
: |
Stranded |
Conductor Resistance |
: |
26 Ω/km |
Conductor Material |
: |
Copper |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
PVC |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
18 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
775-6097 |
Cross Sectional Area |
: |
0.75 mm² |
Number of Cores |
: |
2 |
Sheath Colour |
: |
White |
Length |
: |
100m |
Cable Type |
: |
3182Y |
Current Rating |
: |
6 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
6.05mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V, 500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Conductor Resistance |
: |
26 Ω/km |
Conductor Material |
: |
Copper |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
PVC |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
18 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
775-6107 |
Cross Sectional Area |
: |
1.5 mm² |
Number of Cores |
: |
2 |
Sheath Colour |
: |
White |
Length |
: |
100m |
Cable Type |
: |
3182Y |
Current Rating |
: |
16 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
7.3mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V, 500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Conductor Resistance |
: |
13.3 Ω/km |
Conductor Material |
: |
Copper |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
PVC |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
15 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
775-6157 |
Cross Sectional Area |
: |
1.5 mm² |
Number of Cores |
: |
4 |
Sheath Colour |
: |
Black |
Length |
: |
100m |
Cable Type |
: |
3184Y |
Current Rating |
: |
16 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
8.87mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V, 500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Conductor Resistance |
: |
13.3 Ω/km |
Conductor Material |
: |
Copper |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
PVC |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
15 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
902-8303 |
Cross Sectional Area |
: |
1.5 mm² |
Number of Cores |
: |
4 |
Sheath Colour |
: |
Black |
Length |
: |
50m |
Cable Type |
: |
NYY-J |
CPR Certification |
: |
Eca |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
1 kV |
Conductor Strand Type |
: |
Solid |
Size of Strands |
: |
1.365 mm |
Conductor Resistance |
: |
12.1 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-5°C |
Standards Met |
: |
EN 50265-2-1, IEC 60228 Class 1, IEC 60332-1, IEC 60502-1 |
Insulation material |
: |
PVC |
Fire Behaviour |
: |
Flame Retardant |
Maximum Operating Temperature |
: |
+70°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
902-8363 |
Cross Sectional Area |
: |
1.5 mm² |
Number of Cores |
: |
6 |
Sheath Colour |
: |
Grey |
Length |
: |
100m |
Cable Type |
: |
NYM-J |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
11 → 13mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V, 500 V |
Conductor Strand Type |
: |
Solid |
Conductor Resistance |
: |
12.1 Ω/km |
Minimum Operating Temperature |
: |
-5°C |
Standards Met |
: |
HD 21.4 S2, IEC 60288, IEC 60332-1 |
Insulation material |
: |
PVC |
Fire Behaviour |
: |
Flame Retardant |
Maximum Operating Temperature |
: |
+70°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
836-0690 |
Cross Sectional Area |
: |
1.5 mm² |
Number of Cores |
: |
3 |
Length |
: |
100m |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
9.2 → 11.9mm |
Sheath Material |
: |
Cross-Linked Compound, Type EM 8 to EN 50363-6 |
Voltage Rating |
: |
750 V |
European Harmonised Code |
: |
H07ZZ-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
27 |
Size of Strands |
: |
0.25 mm |
Conductor Resistance |
: |
13.3 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-5°C |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
Cross Linked |
Core Strands |
: |
27/0.25 mm |
Maximum Operating Temperature |
: |
+90°C |
American Wire Gauge |
: |
15 AWG |
Cable Shape |
: |
Round |
|
Brand |
: |
RS PRO |
MFR # |
: |
836-0741 |
Cross Sectional Area |
: |
0.75 mm² |
Number of Cores |
: |
4 |
Sheath Colour |
: |
White |
Length |
: |
100m |
Cable Type |
: |
Fire Performance |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
6.6 → 8.3mm |
Voltage Rating |
: |
500 V |
European Harmonised Code |
: |
H05Z1Z1-F |
Number of Strands |
: |
22 |
Size of Strands |
: |
0.2 mm |
Conductor Resistance |
: |
26 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-5°C |
Standards Met |
: |
BS EN 50525 |
Insulation material |
: |
Thermoplastic |
Fire Behaviour |
: |
Flame Retardant |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
18 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
775-6154 |
Cross Sectional Area |
: |
1 mm² |
Number of Cores |
: |
4 |
Sheath Colour |
: |
White |
Length |
: |
100m |
Cable Type |
: |
3184Y |
Current Rating |
: |
10 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
7.81mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V, 500 V |
European Harmonised Code |
: |
H05VV-F |
Conductor Strand Type |
: |
Stranded |
Conductor Resistance |
: |
19.5 Ω/km |
Conductor Material |
: |
Copper |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
PVC |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
17 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
773-9061 |
Cross Sectional Area |
: |
1.5 mm² |
Number of Cores |
: |
4 |
Sheath Colour |
: |
Black |
Length |
: |
100m |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
11.1mm |
Sheath Material |
: |
CPE |
Voltage Rating |
: |
450 V, 750 V |
European Harmonised Code |
: |
H07RN-F |
Conductor Strand Type |
: |
Stranded |
Number of Strands |
: |
30 |
Size of Strands |
: |
0.24 mm |
Conductor Resistance |
: |
13.3 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-25°C |
Standards Met |
: |
VDE 0285-525-2-21 |
Insulation material |
: |
EPR |
Core Strands |
: |
30/0.24 mm |
Fire Behaviour |
: |
Flame Retardant |
Maximum Operating Temperature |
: |
+60°C |
American Wire Gauge |
: |
15 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
902-8307 |
Cross Sectional Area |
: |
2.5 mm² |
Number of Cores |
: |
4 |
Sheath Colour |
: |
Black |
Length |
: |
50m |
Cable Type |
: |
NYY-J |
CPR Certification |
: |
Eca |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
1 kV, 600 V |
Conductor Strand Type |
: |
Solid |
Size of Strands |
: |
1.75 mm |
Conductor Resistance |
: |
7.41 Ω/km |
Conductor Material |
: |
Copper |
Minimum Operating Temperature |
: |
-5°C |
Standards Met |
: |
EN 50265-2-1, IEC 60228 Class 1, IEC 60332-1, IEC 60502-1, RoHS Compliant |
Insulation material |
: |
PVC |
Fire Behaviour |
: |
Flame Retardant |
Maximum Operating Temperature |
: |
+70°C |
|
Brand |
: |
RS PRO |
MFR # |
: |
775-5833 |
Cross Sectional Area |
: |
0.5 mm² |
Number of Cores |
: |
2 |
Sheath Colour |
: |
Grey |
Length |
: |
100m |
Cable Type |
: |
2182Y |
Current Rating |
: |
3 A |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
5.06mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V |
European Harmonised Code |
: |
H03VV-F |
Conductor Strand Type |
: |
Stranded |
Conductor Resistance |
: |
39 Ω/km |
Conductor Material |
: |
Copper |
Standards Met |
: |
Euroclass Eca |
Insulation material |
: |
PVC |
Maximum Operating Temperature |
: |
+70°C |
American Wire Gauge |
: |
20 AWG |
|
Brand |
: |
RS PRO |
MFR # |
: |
902-8338 |
Cross Sectional Area |
: |
4 mm² |
Number of Cores |
: |
3 |
Sheath Colour |
: |
Grey |
Length |
: |
100m |
Cable Type |
: |
NYM-J |
CPR Certification |
: |
Eca |
Outer Diameter |
: |
11 → 13mm |
Sheath Material |
: |
PVC |
Voltage Rating |
: |
300 V, 500 V |
Conductor Strand Type |
: |
Solid |
Size of Strands |
: |
2.19 mm |
Conductor Resistance |
: |
4.61 Ω/km |
Minimum Operating Temperature |
: |
-5°C |
Standards Met |
: |
HD 21.4 S2, IEC 60288, IEC 60332-1 |
Insulation material |
: |
PVC |
Fire Behaviour |
: |
Flame Retardant |
Maximum Operating Temperature |
: |
+70°C |
|