Brand | : | ABB |
MFR # | : | 2CMA103571R1000 C11 110-101 MID |
Display Type | : | LCD |
Number Of Digits | : | 6 |
Number of Phases | : | 1 |
Number of Inputs | : | 1 |
Number of Outputs | : | 1 |
Pulse Output | : | Yes |
Depth | : | 65mm |
Meter Accuracy | : | 1 % |
Minimum Temperature | : | -25°C |
Maximum Temperature | : | +70°C |
Series | : | C11 |
Meter Type | : | Electronic |
Measurement Range | : | 2 → 100 mA, 5 → 40V dc |
Minimum Measurement | : | 2 mA, 5 V dc |
Maximum Measurement | : | 40 V dc, 100 mA |
Brand | : | Chauvin Arnoux Energy |
MFR # | : | P01330740 |
Display Type | : | LCD |
Number Of Digits | : | 7 |
Number of Phases | : | 1 |
Pulse Output | : | Yes |
Depth | : | 63mm |
Meter Accuracy | : | Class 1 |
Minimum Temperature | : | -25°C |
Maximum Temperature | : | +55°C |
Series | : | MEMO MD32 |
Meter Type | : | Digital |
Measurement Range | : | 0 → 99999.9kWh |
Minimum Measurement | : | 0kWh |
Brand | : | Schneider Electric |
MFR # | : | A9MEM2100 |
Display Type | : | LCD |
Number Of Digits | : | 5 |
Number of Phases | : | 1 |
Depth | : | 65mm |
Minimum Temperature | : | -20°C |
Maximum Temperature | : | +70°C |
Series | : | Acti 9 iEM2000 |
Meter Type | : | Electronic |
Measurement Range | : | 0 → 999.99 MWh, 45 → 65 Hz, Maximum of 63A |
Approvals | : | CE, IEC 60529, IEC 61557-12, IEC 62053-21 |
Minimum Measurement | : | 0 MWh, 45 Hz |
Maximum Measurement | : | 63 A, 65 Hz, 999.99 MWh |
Brand | : | HOBUT |
MFR # | : | C-TRAN-100A |
Display Type | : | No Display |
Number of Phases | : | 3 |
Depth | : | 59mm |
Meter Accuracy | : | 0.1 (Active) %, 0.1 (Frequency) %, 0.1 (Reactive Energy) %, 0.2 (Parameters Unless Stated) %, 0.5 (Power Factor) % |
Maximum Temperature | : | +60°C |
Series | : | C-TRAN |
Measurement Range | : | 100 → 330 (L-N) V, 100 → 440 (L-L) V |
Approvals | : | BS 4889, BSEN 60688, CE, cUL, EN 61010-1, EN 61326-2, IEC 1036, IEC 359, IEC 60044-1, IEC 688, IEC 801.EN 55020, UL |
Minimum Measurement | : | 100 (L-L) V, 100 (L-N) V |
Maximum Measurement | : | 330 (L-N) V, 440 (L-L) V |
Brand | : | Schneider Electric |
MFR # | : | METSEPM8244 |
Display Type | : | LCD |
Number of Phases | : | 3 |
Pulse Output | : | Yes |
Depth | : | 90.8mm |
Meter Accuracy | : | ±0.1 (Current, Voltage) %, ±0.2 (Active Energy) % |
Minimum Temperature | : | -25°C |
Maximum Temperature | : | +70°C |
Series | : | PM8000 |
Meter Type | : | Electromechanical |
Measurement Range | : | 100 → 690 (Phase) V ac, 42 → 69 Hz, 50 mA → 10 A, 57 → 400 (Phase and Neutral) V ac |
Approvals | : | CE, CSA C22.2 No 61010-1, CULus, EN 61010-1, IEC 60529, IEC 61010-1, IEC 61557-12, IEC 62052-11, IEC 62053-22, IEC 62053-24, N998, UL 61010-1 |
Minimum Measurement | : | 100 (Phase) V ac, 57 (Phase and Neutral) V ac, 42 Hz, 50 mA |
Maximum Measurement | : | 400 (Phase and Neutral) V ac, 690 (Phase) V ac, 10 A, 69 Hz |
Brand | : | Murata Power Solutions |
MFR # | : | ACM20-4-AC1-R-F-C |
Cutout Height | : | 22.1mm |
Cutout Width | : | 36.22mm |
Display Type | : | LED |
Number Of Digits | : | 4 |
Number of Phases | : | 1 |
Depth | : | 23.11mm |
Digit Height | : | 9.14 mm |
Meter Accuracy | : | ±0.1 (Frequency) %, ±2 (Power) % |
Minimum Temperature | : | 0°C |
Maximum Temperature | : | +60°C |
Series | : | ACM20 |
Brand | : | Schneider Electric |
MFR # | : | A9MEM2110 |
Display Type | : | LCD |
Number Of Digits | : | 8 |
Number of Phases | : | 1 |
Pulse Output | : | Yes |
Depth | : | 64mm |
Minimum Temperature | : | -25°C |
Maximum Temperature | : | +70°C |
Series | : | Acti 9 iEM2000 |
Meter Type | : | Electronic |
Measurement Range | : | 0 → 999999.99 kWh, 45 → 65 Hz, Maximum of 63A |
Approvals | : | CE, EN 50470-3, IEC 60529, IEC 62052-11, IEC 62052-31, IEC 62053-21, IEC 62053-23, IEC 62053-31, MID Conforming to EN 50470-1, MID Conforming to EN 50470-3, UL 94 |
Minimum Measurement | : | 0 kWh, 45 Hz |
Maximum Measurement | : | 63 A, 65 Hz, 999999.99 kWh |
Brand | : | ABB |
MFR # | : | 2CMA100180R1000 B24 212-100 |
Display Type | : | LCD |
Number Of Digits | : | 7 |
Number of Phases | : | 3 |
Number of Inputs | : | 1 |
Number of Outputs | : | 1 |
Pulse Output | : | Yes |
Communication Port Type | : | RS485 |
Depth | : | 65mm |
Meter Accuracy | : | 1 % |
Minimum Temperature | : | -40°C |
Maximum Temperature | : | +70°C |
Series | : | B24 |
Meter Type | : | Transformer Connected |
Brand | : | Murata Power Solutions |
MFR # | : | ACM20-4-AC1-R-C |
Cutout Height | : | 22.1mm |
Cutout Width | : | 36.22mm |
Display Type | : | LED |
Number Of Digits | : | 4 |
Number of Phases | : | 1 |
Depth | : | 23.11mm |
Digit Height | : | 9.14 mm |
Meter Accuracy | : | ±3 (Power Factor) % |
Minimum Temperature | : | 0°C |
Maximum Temperature | : | +60°C |
Series | : | ACM20 |
Brand | : | Sifam Tinsley |
MFR # | : | ND20LITE-22100U0 |
Cutout Height | : | 92.5mm |
Cutout Width | : | 92.5mm |
Display Type | : | LCD |
Number Of Digits | : | 16 |
Depth | : | 7.7mm |
Minimum Temperature | : | -25°C |
Maximum Temperature | : | +55°C |
Series | : | ND20LITE |
Meter Type | : | Electrical |
Measurement Range | : | 0.002 → 1.2 (Current A @ 1 A), 0.010 → 6 (Current A @ 5 A), 1.4 VA → 1.65 kVA (Apparent Power), -1.65 → 1.65 (Active Power) kW, -1.65 → 1.65 (Reactive Power) kVA, 11.5 → 276 (Voltage L-N V @ 230 V), 2.8 → 70 (Voltage L-N V @ 57.7 V), 20 → 480 (Voltage L-L V @ 400 V), 47 → 63 (Frequency) Hz, 5 → 120 (Voltage L-L V @ 100 V) |
Approvals | : | CE, EN 61000-6-2, EN 61000-6-4, EN 61010-1 |
Minimum Measurement | : | 0.002 (Current A @ 1 A), 0.010 (Current A @ 5 A), 1.4 (Apparent Power) VA, -1.65 (Active Power) kW, -1.65 (Reactive Power) kVA, 11.5 (Voltage L-N V @ 230 V), 2.8 (Voltage L-N V @ 57.7 V), 20 (Voltage L-L V @ 400 V), 47 (Frequency) Hz, 5 (Voltage L-L V @ 100 V) |
Maximum Measurement | : | 1.2 (Current A @ 1 A), 1.65 (Active Power) kW, 1.65 (Apparent Power) kVA, 1.65 (Reactive Power) kVA, 120 (Voltage L-L V @ 100 V), 276 (Voltage L-N V @ 230 V), 480 (Voltage L-L V @ 400 V), 6 (Current A @ 5 A), 63 (Frequency) Hz, 70 (Voltage L-N V @ 57.7 V) |
Brand | : | Chauvin Arnoux Energy |
MFR # | : | P01330741 |
Display Type | : | LCD |
Number Of Digits | : | 6 |
Number of Phases | : | 1 |
Pulse Output | : | Yes |
Depth | : | 65mm |
Meter Accuracy | : | Class 1 |
Minimum Temperature | : | -25°C |
Maximum Temperature | : | +65°C |
Series | : | MEMO MD65 |
Meter Type | : | Digital |
Measurement Range | : | 0 → 99999.9kWh |
Minimum Measurement | : | 0kWh |
Brand | : | Chauvin Arnoux Energy |
MFR # | : | P01330745 |
Display Type | : | LCD |
Number Of Digits | : | 8 |
Number of Phases | : | 3 |
Pulse Output | : | Yes |
Depth | : | 65mm |
Meter Accuracy | : | Class 1 |
Minimum Temperature | : | -25°C |
Maximum Temperature | : | +65°C |
Series | : | MEMO TD80 |
Meter Type | : | Digital |
Measurement Range | : | 0 → 999999.99kWh |
Minimum Measurement | : | 0kWh |
Brand | : | Schneider Electric |
MFR # | : | METSEPM8243 |
Display Type | : | LCD |
Number of Phases | : | 3 |
Pulse Output | : | Yes |
Depth | : | 90.8mm |
Meter Accuracy | : | ±0.1 (Current) %, ±0.1 (Voltage) %, ±0.2 (Active Energy) % |
Minimum Temperature | : | -25°C |
Maximum Temperature | : | +70°C |
Series | : | PM8000 |
Meter Type | : | Electromechanical |
Measurement Range | : | 100 → 690 (Phase) V ac, 42 → 69 Hz, 50 mA → 10 A, 57 → 400 (Phase and Neutral) V ac |
Approvals | : | CE, CSA C22.2 No 61010-1, CULus, EN 61010-1, IEC 60529, IEC 61010-1, IEC 61557-12, IEC 62052-11, IEC 62053-22, IEC 62053-24, N998, UL 61010-1 |
Minimum Measurement | : | 100 (Phase) V ac, 57 (Phase and Neutral) V ac, 42 Hz, 50 mA |
Maximum Measurement | : | 10 A, 69 Hz, 400 (Phase and Neutral) V ac, 690 (Phase) V ac |
Brand | : | Lovato |
MFR # | : | DMG110 |
Properties Measured | : | Current, Frequency, Power, Power Factor, Voltage |
Display Type | : | LCD |
Depth | : | 63mm |
Minimum Temperature | : | -20°C |
Maximum Temperature | : | +60°C |
Series | : | DMG |
Meter Type | : | Electronic |
Measurement Range | : | 0.1 → 1.1 A, 45 → 66 Hz, 50 → 720 V ac |
Minimum Measurement | : | 0.1 A, 45 Hz, 50 V ac |
Brand | : | Lovato |
MFR # | : | DMG100 |
Properties Measured | : | Current, Frequency, Power, Power Factor, Voltage |
Display Type | : | LCD |
Depth | : | 63mm |
Minimum Temperature | : | -20°C |
Maximum Temperature | : | +60°C |
Series | : | DMG |
Meter Type | : | Electronic |
Measurement Range | : | 0.1 → 1.1 A, 45 → 66 Hz, 50 → 720 V ac |
Minimum Measurement | : | 0.1 A, 45 Hz, 50 V ac |
Brand | : | Schneider Electric |
MFR # | : | A9MEM2000 |
Display Type | : | LCD |
Number Of Digits | : | 7 |
Number of Phases | : | 1 |
Depth | : | 67mm |
Minimum Temperature | : | -20°C |
Maximum Temperature | : | +70°C |
Series | : | Acti 9 iEM2000 |
Meter Type | : | Electromechanical |
Measurement Range | : | 0 → 999999.9 kWh, 48 → 62 Hz, Maximum of 40A |
Approvals | : | CE, IEC 60529, IEC 61557-12, IEC 62053-21, MID |
Minimum Measurement | : | 0 kWh, 48 Hz |
Maximum Measurement | : | 40, 62 Hz, 999999.9 kWh |
Brand | : | HOBUT |
MFR # | : | C-TRAN-250A |
Display Type | : | No Display |
Number of Phases | : | 3 |
Depth | : | 59mm |
Meter Accuracy | : | 0.1 (Active) %, 0.1 (Frequency) %, 0.1 (Reactive Energy) %, 0.2 (Parameters Unless Stated) %, 0.5 (Power Factor) % |
Maximum Temperature | : | +60°C |
Series | : | C-TRAN |
Measurement Range | : | 100 → 330 (L-N) V, 100 → 440 (L-L) V |
Approvals | : | BS 4889, BSEN 60688, CE, cUL, EN 61010-1, EN 61326-2, IEC 1036, IEC 359, IEC 60044-1, IEC 688, IEC 801.EN 55020, UL |
Minimum Measurement | : | 100 (L-L) V, 100 (L-N) V |
Maximum Measurement | : | 330 (L-N) V, 440 (L-L) V |
Brand | : | Lovato |
MFR # | : | DMG210 |
Properties Measured | : | Current, Frequency, Power, Power Factor, Voltage |
Display Type | : | LCD |
Depth | : | 63mm |
Minimum Temperature | : | -20°C |
Maximum Temperature | : | +60°C |
Series | : | DMG |
Meter Type | : | Electronic |
Measurement Range | : | 10 → 480 (Neutral) V ac, 20 → 830 (Phase → Phase) V ac, 45 → 66 Hz, Maximum of 10000 A |
Approvals | : | CSA, cULus Certification, EAC Certification |
Minimum Measurement | : | 10 (Neutral) V ac, 20 (Phase → Phase) V ac |
Brand | : | Murata Power Solutions |
MFR # | : | ACM20-2-AC1-R-C |
Cutout Height | : | 22.1mm |
Cutout Width | : | 36.22mm |
Display Type | : | LED |
Number Of Digits | : | 4 |
Number of Phases | : | 1 |
Depth | : | 23.11mm |
Digit Height | : | 9.14 mm |
Meter Accuracy | : | ±3 (Power Factor) % |
Minimum Temperature | : | 0°C |
Maximum Temperature | : | +60°C |
Series | : | ACM20 |
Brand | : | Siemens |
MFR # | : | 7KM2200-2EA40-1EA1 |
Cutout Height | : | 90mm |
Cutout Width | : | 107.8mm |
Display Type | : | LCD |
Number Of Digits | : | 12 |
Number of Phases | : | 3 |
Number of Inputs | : | 1 |
Number of Outputs | : | 1 |
Communication Port Type | : | MODBUS TCP |
Depth | : | 71.4mm |
Series | : | SENTRON PAC2200 |
Meter Type | : | Digital |
Measurement Range | : | 230 → 400V |
Approvals | : | CE |
Maximum Measurement | : | 1 MΩ, 65 Hz, 65 A, 400 V ac |
Brand | : | Sifam Tinsley |
MFR # | : | N43-12100U0 |
Display Type | : | LCD |
Depth | : | 60mm |
Minimum Temperature | : | -10°C |
Maximum Temperature | : | +55°C |
Series | : | N43 |
Meter Type | : | Electrical |
Measurement Range | : | 0 → 999 kVA, 0 → 999 kvar, 0 → 999 kW, 0 → 999 MVA, 0 → 999 MVar, 0 → 999 MW, 0 → 999 VA, 0 → 999 Var, 0 → 999 W, 0 → 999999.9 kVArh, 0 → 999999.9 KWh, 0 → 999999.9 MVArh, 0 → 999999.9 MWh, 0.1 A → 6 kA, -1 → 1, 10 V → 120 kV, 47 → 63Hz |
Approvals | : | EN 61000-6-2, EN 61000-6-4, EN 61010-1 |
Minimum Measurement | : | -1, 0 kVA, 0 kVar, 0 kVArh, 0 kW, 0 KWh, 0 MVA, 0 MVar, 0 MVArh, 0 MW, 0 MWh, 0 VA, 0 Var, 0 W, 0.1 A, 10 V, 47 Hz |
Maximum Measurement | : | 1, 6 kA, 63 Hz, 999 kVA, 999 kVar, 999 kW, 999 MVA, 999 MVar, 999 MW, 999 VA, 999 Var, 999 W, 999999.9 kVArh, 999999.9 KWh, 999999.9 MWh |
Brand | : | ABB |
MFR # | : | 2CMA100166R1000 B23 212-100 |
Cutout Height | : | 26.5mm |
Cutout Width | : | 70mm |
Display Type | : | LCD |
Number Of Digits | : | 7 |
Number of Phases | : | 3 |
Pulse Output | : | Yes |
Depth | : | 65mm |
Meter Accuracy | : | 1 % |
Minimum Temperature | : | -40°C |
Maximum Temperature | : | +70°C |
Series | : | B23 |
Meter Type | : | Digital |
Approvals | : | IEC |
Brand | : | ABB |
MFR # | : | 2CMA100164R1000 B23 112-100 |
Display Type | : | LCD |
Number Of Digits | : | 7 |
Number of Phases | : | 3 |
Number of Inputs | : | 1 |
Pulse Output | : | Yes |
Depth | : | 65mm |
Meter Accuracy | : | Class 1 |
Minimum Temperature | : | -40°C |
Maximum Temperature | : | +70°C |
Series | : | B |
Meter Type | : | Electromechanical |
Measurement Range | : | 220 → 240V ac |
Approvals | : | EN 50470-1, EN 50470-3, EN 55022, GB 4208-2008, GB/T 17215.211-2006, GB/T 17215.321-2008 Class 1 & 2, GB/T 17215.322-2008 Class 0 & 5 S, IEC 60060-1, IEC 60529, IEC 60695-2-1, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 62052-11, IEC 6 |
Brand | : | ABB |
MFR # | : | 2CMA103574R1000 C13 110-101 MID |
Cutout Height | : | 26.5mm |
Cutout Width | : | 54mm |
Display Type | : | LCD |
Number Of Digits | : | 6 |
Number of Phases | : | 3 |
Number of Outputs | : | 1 |
Pulse Output | : | Yes |
Depth | : | 65mm |
Meter Accuracy | : | 1 % |
Minimum Temperature | : | -25°C |
Maximum Temperature | : | +70°C |
Series | : | C13 |
Meter Type | : | Electronic |
Measurement Range | : | 2 → 100 mA, 5 → 40V dc |
Approvals | : | CE |
Minimum Measurement | : | 2 mA, 5 V dc |
Maximum Measurement | : | 40 V dc, 100 mA |
Brand | : | ABB |
MFR # | : | 2CMA100177R1000 B24 111-100 |
Cutout Height | : | 65mm |
Cutout Width | : | 70mm |
Display Type | : | LCD |
Number Of Digits | : | 7 |
Number of Phases | : | 3 |
Number of Outputs | : | 1 |
Pulse Output | : | Yes |
Communication Port Type | : | IR Port |
Depth | : | 65mm |
Meter Accuracy | : | 1 % |
Minimum Temperature | : | -40°C |
Maximum Temperature | : | +70°C |
Series | : | B24 |
Meter Type | : | Transformer Connected |
Approvals | : | IEC |
Brand | : | Chauvin Arnoux Energy |
MFR # | : | P01331036 |
Display Type | : | LCD |
Number Of Digits | : | 8 |
Number of Phases | : | 3 |
Pulse Output | : | Yes |
Depth | : | 65mm |
Minimum Temperature | : | -25°C |
Maximum Temperature | : | +55°C |
Series | : | ULYS |
Meter Type | : | Digital |
Measurement Range | : | 0 → 9999999.9kWh |
Approvals | : | EIA RS485, EN 50470-3, IEC 13757-1-2-3, IEC 62053-21, IEC 62053-23, MID |
Minimum Measurement | : | 0kWh |
Brand | : | Chauvin Arnoux Energy |
MFR # | : | P01331019 |
Display Type | : | LCD |
Number Of Digits | : | 8 |
Number of Phases | : | 3 |
Pulse Output | : | Yes |
Depth | : | 65mm |
Minimum Temperature | : | -25°C |
Maximum Temperature | : | +55°C |
Series | : | ULYS |
Meter Type | : | Digital |
Measurement Range | : | 0 → 9999999.9kWh |
Approvals | : | MID |
Minimum Measurement | : | 0kWh |
Brand | : | Chauvin Arnoux Energy |
MFR # | : | P01331041 |
Display Type | : | LCD |
Number Of Digits | : | 8 |
Number of Phases | : | 3 |
Pulse Output | : | Yes |
Depth | : | 65mm |
Minimum Temperature | : | -25°C |
Maximum Temperature | : | +55°C |
Series | : | ULYS |
Meter Type | : | Digital |
Measurement Range | : | 0 → 99999999kWh |
Approvals | : | EIA RS485, EN 50470-3, IEC 13757-1-2-3, IEC 62053-21, IEC 62053-23, MID |
Minimum Measurement | : | 0kWh |
Brand | : | Chauvin Arnoux Energy |
MFR # | : | P01331018 |
Display Type | : | LCD |
Number Of Digits | : | 8 |
Number of Phases | : | 3 |
Pulse Output | : | Yes |
Depth | : | 65mm |
Minimum Temperature | : | -25°C |
Maximum Temperature | : | +55°C |
Series | : | ULYS |
Meter Type | : | Digital |
Measurement Range | : | 0 → 9999999.9kWh |
Approvals | : | EIA RS485, EN 50470-3, IEC 13757-1-2-3, IEC 62053-21, IEC 62053-23, MID |
Minimum Measurement | : | 0kWh |