Brand |
: |
Panasonic |
MFR # |
: |
TH634 |
Supply Voltage |
: |
24 V ac |
Input Type |
: |
Voltage |
Connection Type |
: |
Tab |
Reset Method |
: |
No Reset |
Mounting Type |
: |
Panel Mount |
Display Range |
: |
0 → 99999.9 |
Maximum Operating Temperature |
: |
+50°C |
Series |
: |
TH63 |
Measurement Range |
: |
0 → 99999.9 |
Minimum Operating Temperature |
: |
-10°C |
Weight |
: |
80g |
|
Brand |
: |
Hengstler |
MFR # |
: |
0 731 103 |
Display Type |
: |
LCD |
Input Type |
: |
Voltage |
Connection Type |
: |
Screw |
Reset Method |
: |
Manual |
Number Of Digits |
: |
8 |
Mounting Type |
: |
Panel Mount |
Digit Height |
: |
7 mm |
Maximum Count Frequency |
: |
30Hz |
Maximum Operating Temperature |
: |
+50°C |
Series |
: |
TICO 731 |
Minimum Operating Temperature |
: |
-10°C |
|
Brand |
: |
Kübler |
MFR # |
: |
1.710.200.009 |
Count Mode |
: |
Impulses |
Input Type |
: |
Voltage |
Connection Type |
: |
Flying Lead |
Reset Method |
: |
No Reset |
Number Of Digits |
: |
7 |
Mounting Type |
: |
Panel Mount |
Count Direction |
: |
Up |
Digit Height |
: |
4 mm |
Maximum Count Frequency |
: |
10Hz |
Maximum Operating Temperature |
: |
+60°C |
Series |
: |
K 47.20 |
Minimum Operating Temperature |
: |
-10°C |
Weight |
: |
12 → 14g |
|
Brand |
: |
Baumer |
MFR # |
: |
M 310.R10A06C |
Reset Method |
: |
Manual |
Number Of Digits |
: |
5 |
Count Direction |
: |
Top Going |
Digit Height |
: |
4.5 mm |
Drive Shaft Diameter |
: |
4mm |
Shaft Speed Maximum |
: |
300rpm |
|
Brand |
: |
Kübler |
MFR # |
: |
0.135.100.373 |
Supply Voltage |
: |
10 → 80 V dc |
Input Type |
: |
Voltage |
Connection Type |
: |
Tab |
Reset Method |
: |
No Reset |
Number Of Digits |
: |
6 |
Mounting Type |
: |
Chassis Mount |
Count Direction |
: |
Up |
Digit Height |
: |
3.5 mm |
Display Range |
: |
0 → 99999.9 |
Maximum Operating Temperature |
: |
+65°C |
Series |
: |
HR 76.1 |
Measurement Range |
: |
0 → 99999.9 |
Minimum Operating Temperature |
: |
-30°C |
Weight |
: |
56g |
|
Brand |
: |
Kübler |
MFR # |
: |
6.130.012.853 |
Count Mode |
: |
Impulses |
Display Type |
: |
LCD |
Input Type |
: |
Voltage |
Connection Type |
: |
Screw |
Reset Method |
: |
Electrical, Manual |
Number Of Digits |
: |
8 |
Mounting Type |
: |
Panel Mount |
Count Direction |
: |
Bi-Directional |
Digit Height |
: |
8 mm |
Maximum Count Frequency |
: |
30Hz |
Display Range |
: |
-9999999 → 99999999 |
Maximum Operating Temperature |
: |
+55°C |
Series |
: |
CODIX 130 |
Measurement Range |
: |
-9999999 → 99999999 |
Minimum Operating Temperature |
: |
-10°C |
Weight |
: |
50g |
|
Brand |
: |
Kübler |
MFR # |
: |
6.901.010.820 |
Supply Voltage |
: |
12 → 250 V ac/dc |
Count Mode |
: |
Pulse |
Display Type |
: |
LCD |
Input Type |
: |
Voltage |
Connection Type |
: |
Screw |
Reset Method |
: |
Key, Lock |
Number Of Digits |
: |
6 |
Mounting Type |
: |
Panel Mount |
Output / Interface |
: |
Relay |
Count Direction |
: |
Bi-Directional |
Digit Height |
: |
7 mm |
Maximum Count Frequency |
: |
30Hz |
Cutout Size |
: |
45 x 45 mm |
Function |
: |
Counter |
Maximum Operating Temperature |
: |
+65°C |
Approvals |
: |
cULus, E128604, EN 55011 class B, EN 61000-6-2, EN 61010-1, EN 61326-1 |
Series |
: |
CODIX 901 |
Measurement Range |
: |
0 → 999999 |
Meter Type |
: |
Electronic |
Minimum Measurement |
: |
0 |
Cutout Height |
: |
45mm |
Cutout Width |
: |
45mm |
Minimum Operating Temperature |
: |
-20°C |
Depth |
: |
66.2mm |
|
Brand |
: |
Trumeter |
MFR # |
: |
6320-0000-0000 |
Supply Voltage |
: |
-0.5 → 30 V dc, 300 V ac/dc |
Count Mode |
: |
Hours |
Display Type |
: |
LCD |
Input Type |
: |
Voltage |
Connection Type |
: |
Terminal Block |
Reset Method |
: |
Manual, No Reset, Remote |
Number Of Digits |
: |
7 (Annunciators Icon), 8 (Figure) |
Mounting Type |
: |
Panel Mount |
Output / Interface |
: |
Voltage |
Digit Height |
: |
2 (Annunciators Icon) mm, 8 (Figure) mm |
Cutout Size |
: |
45.5 x 22.6 mm |
Function |
: |
Hour Meter |
Approvals |
: |
CE, cUL Recognized, RoHS, UL, WEEE |
Series |
: |
6320 |
Measurement Range |
: |
0 → 99999999 |
Meter Accuracy |
: |
100% |
Meter Type |
: |
Electronic |
Minimum Measurement |
: |
0 |
Cutout Height |
: |
22.6mm |
Cutout Width |
: |
45.5mm |
Minimum Operating Temperature |
: |
-20°C |
Depth |
: |
38mm |
|
Brand |
: |
Kübler |
MFR # |
: |
0.135.200.302 |
Supply Voltage |
: |
230 V ac |
Input Type |
: |
Voltage |
Connection Type |
: |
Tab |
Reset Method |
: |
No Reset |
Number Of Digits |
: |
6 |
Mounting Type |
: |
Clip |
Count Direction |
: |
Up |
Digit Height |
: |
3.5 mm |
Display Range |
: |
0 → 99999.9 |
Maximum Operating Temperature |
: |
+65°C |
Series |
: |
HR 76.2 |
Measurement Range |
: |
0 → 99999.9 |
Minimum Operating Temperature |
: |
-30°C |
Weight |
: |
54g |
|
Brand |
: |
Red Lion |
MFR # |
: |
CUB7TCS0 |
Supply Voltage |
: |
28 V dc |
Display Type |
: |
LCD |
Input Type |
: |
Voltage |
Connection Type |
: |
Plug-In |
Number Of Digits |
: |
8 |
Mounting Type |
: |
Panel Mount |
Digit Height |
: |
8.9 mm |
Maximum Count Frequency |
: |
10kHz |
Display Range |
: |
0 → 99999999 |
Maximum Operating Temperature |
: |
+50°C |
Measurement Range |
: |
0 → 99999999 |
Minimum Operating Temperature |
: |
0°C |
Weight |
: |
50g |
|
Brand |
: |
Kübler |
MFR # |
: |
1.150.510.013.550 |
Supply Voltage |
: |
24 V dc |
Count Mode |
: |
Impulses |
Input Type |
: |
Voltage |
Connection Type |
: |
Flying Lead |
Reset Method |
: |
Manual |
Number Of Digits |
: |
5 |
Mounting Type |
: |
Panel Mount |
Count Direction |
: |
Up |
Digit Height |
: |
4 mm |
Maximum Count Frequency |
: |
10Hz |
Maximum Operating Temperature |
: |
+50°C |
Series |
: |
W15.51 |
Minimum Operating Temperature |
: |
-10°C |
Weight |
: |
62g |
|
Brand |
: |
Kübler |
MFR # |
: |
6.134.012.853 |
Supply Voltage |
: |
10 → 260 V ac/dc |
Display Type |
: |
LCD |
Input Type |
: |
Voltage |
Connection Type |
: |
Screw |
Reset Method |
: |
Electrical, Manual |
Number Of Digits |
: |
8 |
Mounting Type |
: |
Panel Mount |
Digit Height |
: |
8 mm |
Display Range |
: |
0 → 99999.99 |
Maximum Operating Temperature |
: |
+55°C |
Series |
: |
CODIX 134 |
Measurement Range |
: |
0 → 99999.99 |
Minimum Operating Temperature |
: |
-10°C |
Weight |
: |
50g |
|
Brand |
: |
Kübler |
MFR # |
: |
3.130.251.351.056 |
Supply Voltage |
: |
10 → 30 V dc |
Input Type |
: |
Voltage |
Connection Type |
: |
Screw |
Reset Method |
: |
No Reset |
Number Of Digits |
: |
8 |
Digit Height |
: |
3.8 mm |
Display Range |
: |
0 → 999999.99 |
Maximum Operating Temperature |
: |
+50°C |
Series |
: |
HK 17.251 |
Measurement Range |
: |
0 → 999999.99 |
Minimum Operating Temperature |
: |
-15°C |
Weight |
: |
40g |
|
Brand |
: |
Kübler |
MFR # |
: |
6.924.0103.300 |
Supply Voltage |
: |
10 → 30 V dc |
Count Mode |
: |
Frequency, Pulse, Time |
Display Type |
: |
LCD |
Input Type |
: |
Voltage |
Connection Type |
: |
Screw |
Reset Method |
: |
Gate, Lock |
Number Of Digits |
: |
6 |
Mounting Type |
: |
Panel Mount |
Output / Interface |
: |
Relay |
Count Direction |
: |
Bi-Directional |
Maximum Count Frequency |
: |
65kHz |
Display Range |
: |
-999999 → 999999 |
Maximum Operating Temperature |
: |
+65°C |
Series |
: |
CODIX 924 |
Measurement Range |
: |
-999999 → 999999 |
Minimum Operating Temperature |
: |
-20°C |
Weight |
: |
125g |
|
Brand |
: |
Omron |
MFR # |
: |
H7EC-NV-BH |
Supply Voltage |
: |
24 V dc |
Display Type |
: |
LCD |
Input Type |
: |
Voltage |
Connection Type |
: |
Screw |
Reset Method |
: |
Manual |
Number Of Digits |
: |
8 |
Mounting Type |
: |
Panel Mount |
Count Direction |
: |
Up |
Digit Height |
: |
8.6 mm |
Maximum Count Frequency |
: |
1kHz |
Display Range |
: |
0 → 99999999 |
Maximum Operating Temperature |
: |
+55°C |
Series |
: |
H7EC |
Measurement Range |
: |
0 → 99999999 |
Minimum Operating Temperature |
: |
-10°C |
Weight |
: |
65g |
|
Brand |
: |
Trumeter |
MFR # |
: |
7110DIN |
Count Mode |
: |
Pulse |
Display Type |
: |
LCD |
Input Type |
: |
Voltage |
Connection Type |
: |
Screw |
Reset Method |
: |
External, Manual, Negative Edge Triggered, Push Button |
Number Of Digits |
: |
8 |
Mounting Type |
: |
Panel Mount |
Output / Interface |
: |
CMOS |
Digit Height |
: |
7 mm |
Maximum Count Frequency |
: |
10kHz |
Cutout Size |
: |
45.5 x 22.5 mm |
Function |
: |
Counter |
Maximum Operating Temperature |
: |
+60°C |
Approvals |
: |
CE, cULus |
Series |
: |
7110 |
Measurement Range |
: |
0 → 99999999 |
Meter Type |
: |
Electronic |
Minimum Measurement |
: |
0 |
Cutout Height |
: |
22.5mm |
Cutout Width |
: |
45.5mm |
Minimum Operating Temperature |
: |
-10°C |
Depth |
: |
24mm |
|
Brand |
: |
Hengstler |
MFR # |
: |
0 731 104 |
Display Type |
: |
LCD |
Input Type |
: |
Voltage |
Connection Type |
: |
Screw |
Reset Method |
: |
Manual |
Number Of Digits |
: |
8 |
Mounting Type |
: |
Panel Mount |
Digit Height |
: |
7 mm |
Maximum Count Frequency |
: |
30Hz |
Maximum Operating Temperature |
: |
+50°C |
Series |
: |
TICO 731 |
Minimum Operating Temperature |
: |
-10°C |
|
Brand |
: |
Kübler |
MFR # |
: |
6.140.012.300 |
Supply Voltage |
: |
10 → 30 V dc |
Count Mode |
: |
Impulses |
Display Type |
: |
LCD |
Input Type |
: |
Voltage |
Connection Type |
: |
Screw |
Reset Method |
: |
Electrical, Manual |
Number Of Digits |
: |
7 |
Mounting Type |
: |
Panel Mount |
Count Direction |
: |
Up |
Digit Height |
: |
8 mm |
Maximum Count Frequency |
: |
8kHz |
Display Range |
: |
0 → 9999999 |
Maximum Operating Temperature |
: |
+65°C |
Series |
: |
CODIX 140 |
Measurement Range |
: |
0 → 9999999 |
Minimum Operating Temperature |
: |
-20°C |
Maximum Temperature |
: |
+65°C |
Weight |
: |
40g |
|
Brand |
: |
Trumeter |
MFR # |
: |
7000AS |
Supply Voltage |
: |
2.6 → 3.4 V dc |
Count Mode |
: |
Frequency |
Display Type |
: |
LCD |
Input Type |
: |
Logic |
Connection Type |
: |
Lead |
Reset Method |
: |
External |
Number Of Digits |
: |
6 |
Mounting Type |
: |
Panel Mount, PCB Mount |
Count Direction |
: |
Bi-Directional |
Digit Height |
: |
6 mm |
Maximum Count Frequency |
: |
10kHz |
Cutout Size |
: |
29.4 x 22 mm |
Function |
: |
Totalizer Counter |
Maximum Operating Temperature |
: |
+60°C |
Approvals |
: |
CE, CSA, cUL, UL |
Measurement Range |
: |
0 → 999999 |
Meter Type |
: |
Electronic |
Minimum Measurement |
: |
0 |
Cutout Height |
: |
22mm |
Cutout Width |
: |
29.4mm |
Minimum Operating Temperature |
: |
-10°C |
Depth |
: |
6.5mm |
|
Brand |
: |
Kübler |
MFR # |
: |
6.521.012.300 |
Supply Voltage |
: |
10 → 30 V dc |
Count Mode |
: |
Impulses |
Display Type |
: |
LED |
Input Type |
: |
Voltage |
Reset Method |
: |
Electrical, Manual |
Number Of Digits |
: |
6 |
Mounting Type |
: |
Panel Mount |
Count Direction |
: |
Bi-Directional |
Digit Height |
: |
8 mm |
Maximum Count Frequency |
: |
60kHz |
Display Range |
: |
0.0001 → 999999 |
Maximum Operating Temperature |
: |
+65°C |
Series |
: |
CODIX 521 |
Measurement Range |
: |
0.0001 → 999999 |
Minimum Operating Temperature |
: |
-20°C |
Weight |
: |
50g |
|
Brand |
: |
Kübler |
MFR # |
: |
3.474.911.373 |
Supply Voltage |
: |
10 → 80 V dc |
Input Type |
: |
Voltage |
Connection Type |
: |
Screw |
Reset Method |
: |
No Reset |
Number Of Digits |
: |
7 |
Digit Height |
: |
4 mm |
Display Range |
: |
0 → 999999.9 |
Maximum Operating Temperature |
: |
+70°C |
Series |
: |
HR 47 |
Measurement Range |
: |
0 → 999999.9 |
Minimum Operating Temperature |
: |
-20°C |
Weight |
: |
50g |
|
Brand |
: |
Kübler |
MFR # |
: |
3.220.401.074 |
Supply Voltage |
: |
100 → 130 V ac |
Input Type |
: |
Voltage |
Connection Type |
: |
Screw |
Reset Method |
: |
No Reset |
Number Of Digits |
: |
7 |
Mounting Type |
: |
Panel Mount |
Digit Height |
: |
4 mm |
Display Range |
: |
0 → 99999.99 |
Maximum Operating Temperature |
: |
+50°C |
Series |
: |
H 57 |
Measurement Range |
: |
0 → 99999.99 |
Minimum Operating Temperature |
: |
-15°C |
Weight |
: |
48g |
|
Brand |
: |
Kübler |
MFR # |
: |
3.220.401.351 |
Supply Voltage |
: |
10 → 30 V dc |
Input Type |
: |
Voltage |
Connection Type |
: |
Screw |
Reset Method |
: |
No Reset |
Number Of Digits |
: |
8 |
Mounting Type |
: |
Panel Mount |
Digit Height |
: |
4 mm |
Display Range |
: |
0 → 999999.99 |
Maximum Operating Temperature |
: |
+50°C |
Series |
: |
H 57 |
Measurement Range |
: |
0 → 999999.99 |
Minimum Operating Temperature |
: |
-15°C |
Weight |
: |
48g |
|
Brand |
: |
Panasonic |
MFR # |
: |
TH638CEJ |
Supply Voltage |
: |
220 V ac |
Input Type |
: |
Voltage |
Connection Type |
: |
Tab |
Reset Method |
: |
No Reset |
Number Of Digits |
: |
6 |
Mounting Type |
: |
Panel Mount |
Display Range |
: |
0 → 99999.9 |
Maximum Operating Temperature |
: |
+50°C |
Series |
: |
TH63 |
Measurement Range |
: |
0 → 99999.9 |
Minimum Operating Temperature |
: |
-10°C |
Weight |
: |
80g |
|
Brand |
: |
Trumeter |
MFR # |
: |
3410-1000 |
Supply Voltage |
: |
10 → 300 V dc, 20 → 300 V ac |
Count Mode |
: |
Hours |
Display Type |
: |
LCD |
Input Type |
: |
Voltage |
Connection Type |
: |
Spade Terminal |
Reset Method |
: |
No Reset |
Number Of Digits |
: |
8 |
Mounting Type |
: |
Panel Mount |
Output / Interface |
: |
MOSFET |
Count Direction |
: |
Bi-Directional |
Digit Height |
: |
7 mm |
Maximum Count Frequency |
: |
50 Hz, 60Hz |
Cutout Size |
: |
36.8 x 24.1 mm |
Function |
: |
Hour Meter |
Approvals |
: |
CE, cUL Recognized (File # ELIY2.E36690), NEMA 4, NEMA 4x, RoHS Compliant, SAE, UL, WEEE |
Series |
: |
3410 |
Measurement Range |
: |
0 → 999999.99 h, 0 → 9999999.9h |
Meter Accuracy |
: |
± 0.1 (Room Temperature) %, ± 0.2 (Specified Temperature Range) % |
Meter Type |
: |
Electronic |
Minimum Measurement |
: |
0h |
Cutout Height |
: |
24.1mm |
Cutout Width |
: |
36.8mm |
Minimum Operating Temperature |
: |
-40°C |
Depth |
: |
19mm |
|
Brand |
: |
Kübler |
MFR # |
: |
1.660.200.013 |
Supply Voltage |
: |
24 V dc |
Count Mode |
: |
Impulses |
Input Type |
: |
Voltage |
Connection Type |
: |
Flying Lead |
Reset Method |
: |
No Reset |
Number Of Digits |
: |
7 |
Mounting Type |
: |
Panel Mount |
Count Direction |
: |
Up |
Digit Height |
: |
4 mm |
Maximum Count Frequency |
: |
10Hz |
Maximum Operating Temperature |
: |
+60°C |
Series |
: |
K 67.20 |
Minimum Operating Temperature |
: |
-10°C |
Weight |
: |
9 → 11g |
|
Brand |
: |
Kübler |
MFR # |
: |
6.141.012.300 |
Supply Voltage |
: |
10 → 30 V dc |
Display Type |
: |
LCD |
Input Type |
: |
Voltage |
Connection Type |
: |
Screw |
Reset Method |
: |
Electrical, Manual |
Number Of Digits |
: |
7 |
Mounting Type |
: |
Panel Mount |
Digit Height |
: |
8 mm |
Display Range |
: |
0 → 99999.99 |
Maximum Operating Temperature |
: |
+65°C |
Series |
: |
CODIX 141 |
Measurement Range |
: |
0 → 99999.99 |
Minimum Operating Temperature |
: |
-20°C |
Weight |
: |
40g |
|
Brand |
: |
Kübler |
MFR # |
: |
3.060.200.383 |
Supply Voltage |
: |
4.5 → 35 V dc |
Input Type |
: |
Voltage |
Connection Type |
: |
Wire Lead |
Reset Method |
: |
No Reset |
Number Of Digits |
: |
7 |
Mounting Type |
: |
Panel Mount |
Digit Height |
: |
4 mm |
Display Range |
: |
0 → 99999.99 |
Maximum Operating Temperature |
: |
+60°C |
Series |
: |
HK 47.20 |
Measurement Range |
: |
0 → 99999.99 |
Minimum Operating Temperature |
: |
-10°C |
Weight |
: |
15g |
|
Brand |
: |
Muller |
MFR # |
: |
BW 40.28 230V |
Supply Voltage |
: |
230 V ac |
Count Mode |
: |
Hours |
Input Type |
: |
Voltage |
Connection Type |
: |
Screw |
Reset Method |
: |
No Reset |
Number Of Digits |
: |
5 |
Mounting Type |
: |
Panel Mount |
Digit Height |
: |
4.4 mm |
Display Range |
: |
0 → 99999 |
Cutout Size |
: |
46 x 46 mm |
Function |
: |
Hour Meter |
Maximum Operating Temperature |
: |
+55°C |
Series |
: |
BW40 |
Measurement Range |
: |
0 → 99999 |
Meter Accuracy |
: |
0.01h |
Cutout Height |
: |
46mm |
Cutout Width |
: |
46mm |
Minimum Operating Temperature |
: |
-15°C |
Depth |
: |
38mm |
|
Brand |
: |
Honeywell |
MFR # |
: |
LM-HH4AS-H21 |
Supply Voltage |
: |
9 → 64 V |
Display Type |
: |
LCD |
Input Type |
: |
Voltage |
Connection Type |
: |
Terminal |
Number Of Digits |
: |
6 |
Mounting Type |
: |
Panel Mount |
Digit Height |
: |
7 mm |
Maximum Count Frequency |
: |
500Hz |
Display Range |
: |
0 → 99999.9 h |
Maximum Operating Temperature |
: |
+85°C |
Measurement Range |
: |
0 → 99999.9h |
Minimum Operating Temperature |
: |
-40°C |
|
Brand |
: |
Kübler |
MFR # |
: |
0.135.100.302 |
Supply Voltage |
: |
230 V ac |
Input Type |
: |
Voltage |
Connection Type |
: |
Tab |
Reset Method |
: |
No Reset |
Number Of Digits |
: |
6 |
Mounting Type |
: |
Chassis Mount |
Count Direction |
: |
Up |
Digit Height |
: |
3.5 mm |
Display Range |
: |
0 → 99999.9 |
Maximum Operating Temperature |
: |
+65°C |
Series |
: |
HR 76.1 |
Measurement Range |
: |
0 → 99999.9 |
Minimum Operating Temperature |
: |
-30°C |
Weight |
: |
56g |
|
Brand |
: |
Elesa |
MFR # |
: |
CE.82183-rb |
Number Of Digits |
: |
5 |
Count Direction |
: |
Top Going |
Drive Shaft Diameter |
: |
20mm |
Shaft Speed Maximum |
: |
1250rpm |
|
Brand |
: |
GIC |
MFR # |
: |
LA25F1 |
Supply Voltage |
: |
90 → 264 V ac |
Input Type |
: |
Voltage |
Connection Type |
: |
Spade Terminal |
Reset Method |
: |
No Reset |
Number Of Digits |
: |
6 |
Mounting Type |
: |
Panel Mount |
Digit Height |
: |
3.6 mm |
Display Range |
: |
99999.9 |
Maximum Operating Temperature |
: |
+85°C |
Measurement Range |
: |
99999.9 |
Minimum Operating Temperature |
: |
-40°C |
Weight |
: |
47g |
|
Brand |
: |
Kübler |
MFR # |
: |
1.740.500.012.550 |
Supply Voltage |
: |
12 V dc |
Count Mode |
: |
Impulses |
Input Type |
: |
Voltage |
Connection Type |
: |
Flying Lead |
Reset Method |
: |
No Reset |
Number Of Digits |
: |
7 |
Mounting Type |
: |
Panel Mount |
Count Direction |
: |
Up |
Digit Height |
: |
4 mm |
Maximum Count Frequency |
: |
10Hz |
Maximum Operating Temperature |
: |
+50°C |
Series |
: |
W17.50 |
Minimum Operating Temperature |
: |
-10°C |
Weight |
: |
50g |
|
Brand |
: |
Lascar |
MFR # |
: |
EMC 1500 |
Supply Voltage |
: |
27 V dc |
Display Type |
: |
LCD |
Input Type |
: |
Voltage |
Connection Type |
: |
Screw |
Reset Method |
: |
Automatic |
Number Of Digits |
: |
5 |
Mounting Type |
: |
Panel Mount |
Output / Interface |
: |
Pulse |
Count Direction |
: |
Up |
Digit Height |
: |
9 mm |
Display Range |
: |
9999.9 → 99999 |
Maximum Operating Temperature |
: |
+50°C |
Measurement Range |
: |
9999.9 → 99999 |
Minimum Operating Temperature |
: |
0°C |
|
Brand |
: |
Kübler |
MFR # |
: |
3.167.211.351 |
Supply Voltage |
: |
10 → 30 V dc |
Input Type |
: |
Voltage |
Connection Type |
: |
Screw |
Reset Method |
: |
Manual |
Number Of Digits |
: |
6 |
Mounting Type |
: |
Panel Mount |
Digit Height |
: |
4.5 mm |
Display Range |
: |
0 → 99999.9 |
Maximum Operating Temperature |
: |
+50°C |
Series |
: |
HB 26.21 |
Measurement Range |
: |
0 → 99999.9 |
Minimum Operating Temperature |
: |
-15°C |
Weight |
: |
45g |
|
Brand |
: |
Red Lion |
MFR # |
: |
DT800000 |
Supply Voltage |
: |
9 → 28 V dc |
Display Type |
: |
LCD |
Input Type |
: |
Logic, Voltage |
Connection Type |
: |
Screw Clamp Terminal |
Reset Method |
: |
No Reset |
Number Of Digits |
: |
5 |
Mounting Type |
: |
Panel Mount |
Output / Interface |
: |
Voltage |
Digit Height |
: |
15.2 mm |
Maximum Count Frequency |
: |
10Hz |
Cutout Size |
: |
68 x 33 mm |
Function |
: |
Rate Meter |
Maximum Operating Temperature |
: |
+60°C |
Approvals |
: |
CE, EN 61010-1, IEC 1010-1, IEC 529, IP65 (Face Only), Type 4X (Face Only), UL50 |
Series |
: |
DT8 |
Meter Accuracy |
: |
±0.01% |
Meter Type |
: |
Electronic |
Cutout Height |
: |
33mm |
Cutout Width |
: |
68mm |
Minimum Operating Temperature |
: |
0°C |
Depth |
: |
35.1mm |
|
Brand |
: |
Kübler |
MFR # |
: |
3.167.211.075 |
Supply Voltage |
: |
187 → 264 V ac |
Input Type |
: |
Voltage |
Connection Type |
: |
Screw |
Reset Method |
: |
Manual |
Number Of Digits |
: |
6 |
Mounting Type |
: |
Panel Mount |
Digit Height |
: |
4.5 mm |
Display Range |
: |
0 → 9999.99 |
Maximum Operating Temperature |
: |
+50°C |
Series |
: |
HB 26.21 |
Measurement Range |
: |
0 → 9999.99 |
Minimum Operating Temperature |
: |
-15°C |
Weight |
: |
45g |
|
Brand |
: |
Kübler |
MFR # |
: |
3.550.401.075 |
Supply Voltage |
: |
187 → 264 V ac |
Input Type |
: |
Voltage |
Connection Type |
: |
Screw |
Reset Method |
: |
No Reset |
Number Of Digits |
: |
7 |
Mounting Type |
: |
Panel Mount |
Digit Height |
: |
4 mm |
Display Range |
: |
0 → 99999.99 |
Maximum Operating Temperature |
: |
+50°C |
Series |
: |
HC 77 |
Measurement Range |
: |
0 → 99999.99 |
Minimum Operating Temperature |
: |
-15°C |
Weight |
: |
65g |
|
Brand |
: |
Kübler |
MFR # |
: |
3.100.000.383 |
Supply Voltage |
: |
4.5 → 35 V dc |
Input Type |
: |
Voltage |
Connection Type |
: |
Wire Lead |
Reset Method |
: |
No Reset |
Number Of Digits |
: |
7 |
Mounting Type |
: |
Plug In |
Digit Height |
: |
4 mm |
Display Range |
: |
0 → 99999.99 |
Maximum Operating Temperature |
: |
+60°C |
Series |
: |
AHK 07.00 |
Measurement Range |
: |
0 → 99999.99 |
Minimum Operating Temperature |
: |
-10°C |
Weight |
: |
14g |
|