Circuit Trips
181–240 of 352 products — Browse specifications below, then submit an RFQ
Filters
Schneider Electric
440V ac Circuit Trip for use with Compact NSX 100/160/250 Circuit Breakers
Part: LV433805
Range: Compact
Current Rating: 40A
Series: Micrologic 4.2
Schneider Electric
440V ac Circuit Trip for use with Compact NSX 250 Circuit Breakers
Part: LV433803
Range: Compact
Current Rating: 250A
Series: Micrologic 4.2
Schneider Electric
48V ac/dc Undervoltage Release Circuit Trip for use with ARA, ic60 MCB, IDPN Vigi, iSW-NA, RCA, iC65, iC40, iID
Part: A9A26961
Range: Acti 9
Series: IMN
For Use With: ARA, ic60 MCB, IDPN Vigi, iSW-NA, RCA, iC65, iC40, iID
Schneider Electric
690 V ac, 750V dc Circuit Trip for use with Compact NSX 100/160 Circuit Breakers
Part: LV429164
Range: Compact
Current Rating: 25A
Series: TM-G
Schneider Electric
690V ac Circuit Trip for use with Compact NSX 100/160/250 Circuit Breakers
Part: LV429051
Range: Compact
Current Rating: 80A
Series: TM-D
Schneider Electric
440V ac Circuit Trip for use with Compact NSX 630 Circuit Breakers
Part: LV433953
Range: Compact
Current Rating: 570A
Series: Micrologic 7.3 E
Schneider Electric
690 V ac, 750V dc Circuit Trip for use with Compact NSX 100/160 Circuit Breakers
Part: LV429055
Range: Compact
Current Rating: 32A
Series: TM-D
Schneider Electric
690V ac Circuit Trip for use with Compact NSX 100/160/250 Circuit Breakers
Part: LV429072
Range: Compact
Current Rating: 40A
Series: Micrologic 2.2
Schneider Electric
690V ac Circuit Trip for use with Compact NSX 400/630 Circuit Breakers
Part: LV432086
Range: Compact
Current Rating: 250A
Series: Micrologic 2.3
Schneider Electric
690V ac Circuit Trip for use with Compact NSX 100/160/250 Circuit Breakers
Part: LV429075
Range: Compact
Current Rating: 100A
Series: Micrologic 2.2 G
Schneider Electric
690V ac Circuit Trip for use with Compact NSX 160/250 Circuit Breakers
Part: LV431432
Range: Compact
Current Rating: 160A
Series: TM-D
Schneider Electric
690V ac Circuit Trip for use with Compact NSX 160/250 Circuit Breakers
Part: LV431452
Range: Compact
Current Rating: 160A
Series: TM-D
Schneider Electric
440V ac Circuit Trip for use with Compact NSX 100/160/250 Circuit Breakers
Part: LV433801
Range: Compact
Current Rating: 100A
Series: Micrologic 4.2
Schneider Electric
48V ac/dc Undervoltage Release Circuit Trip for use with C60 Series, C120 Series, IDPN Residual Current Device, ID
Part: A9N26961
Range: Acti 9
Series: MN
For Use With: C60 Series, C120 Series, IDPN Residual Current Device, ID Residual Current Device
Schneider Electric
690 V ac, 750V dc Circuit Trip for use with Compact NSX 100/160 Circuit Breakers
Part: LV429163
Range: Compact
Current Rating: 40A
Series: TM-G
Schneider Electric
690V ac Circuit Trip for use with Compact NSX 100/160/250 Circuit Breakers
Part: LV429082
Range: Compact
Current Rating: 40A
Series: Micrologic 2.2
ABB
Isolator Circuit Trip for use with Commanding Load
Part: 2CDE282001R0125 E202/125r
Range: E200
Series: E202
For Use With: Commanding Load
Schneider Electric
690V ac AC/AC Adapter Circuit Trip
Part: VBF02
Range: TeSys VARIO
Current Rating: 12A
Series: VBF
Eaton
110 → 130V ac Undervoltage Release Circuit Trip for use with N(S)2(-4) Series, N(S)3(-4) Series, NZM2(-4)
Part: 259589 NZM2/3-XUHIV110-130AC
Range: XBoard
Series: Eaton Moeller
For Use With: N(S)2(-4) Series, N(S)3(-4) Series, NZM2(-4) Series, NZM3(-4) Series
Schneider Electric
Auto Recloser Circuit Trip for use with Circuit Breaker
Part: A9C70132
Range: Acti 9
Series: iC60
For Use With: Circuit Breaker
Schneider Electric
250V ac Push Button Circuit Trip
Part: 16189
Range: Duo line
Current Rating: 20A
Series: BPclic
Siemens
500V ac Shunt Trip Shunt trip for use with 3RV2 Series Circuit Breakers
Part: 3RV2902-1DS0
Range: SIRIUS
Series: 3RV2
For Use With: 3RV2 Series Circuit Breakers
Siemens
90 → 110V ac Circuit Trip for use with 3RV2 Series Circuit Breakers
Part: 3RV2902-4DF0
Range: SIRIUS
Series: 3RV2
For Use With: 3RV2 Series Circuit Breakers
Eaton
Shunt Release Shunt trip for use with PKE, Shunt release PKZ0(4)
Part: 199337 A-PKZ0(24V50HZ)-PI
Series: Eaton Moeller
For Use With: PKE, Shunt release PKZ0(4)
Type: Shunt Release
Eaton
Shunt Release Shunt trip for use with PKE, Shunt release PKZ0(4)
Part: 199339 A-PKZ0(230V50HZ)-PI
Series: Eaton Moeller
For Use With: PKE, Shunt release PKZ0(4)
Type: Shunt Release
Schneider Electric
220 → 240V ac Undervoltage Release Circuit Trip for use with ARA, ic60 MCB, IDPN Vigi, ild Double Terminal, ilD
Part: A9A26969
Range: Acti 9
Series: iMNx
For Use With: ARA, ic60 MCB, IDPN Vigi, ild Double Terminal, ilD MCB, iSW-NA, RCA
Schneider Electric
48V ac/dc Remote Tripping Device Circuit Trip for use with LR3D Series, LRD Series
Part: LAD703E
Range: TeSys D
Series: LAD
For Use With: LR3D Series, LRD Series
Schneider Electric
220 → 240V ac Undervoltage Release Circuit Trip for use with ARA, ic60 MCB, IDPN Vigi, ild Double Terminal, ilD
Part: A9A26963
Range: Acti 9
Series: iMNs
For Use With: ARA, ic60 MCB, IDPN Vigi, ild Double Terminal, ilD MCB, iSW-NA, RCA
Schneider Electric
690V ac Circuit Trip for use with Compact NSX 630 Circuit Breakers
Part: LV432099
Range: Compact
Current Rating: 630A
Series: Micrologic 5.3 E
Schneider Electric
Shunt trip for use with Multi 9 C60 C60BP, Multi 9 C60 C60BPR, Multi 9 C60 C60SP, Multi 9 C60H-DC, Multi 9 GFP
Part: M9A26947
Range: Multi 9
Current Rating: 6A
Series: M9A
Eaton
208 → 250V ac/dc Shunt Trip Shunt trip for use with N(S)1(-4) Series, NZM1(-4) Series
Part: 259726 NZM1-XA208-250AC/DC
Range: XBoard
Series: Eaton Moeller
For Use With: N(S)1(-4) Series, NZM1(-4) Series
Siemens
210 → 240V ac Shunt Trip Shunt trip for use with 3RV2 Series Circuit Breakers
Part: 3RV2902-2DP0
Range: SIRIUS
Series: 3RV2
For Use With: 3RV2 Series Circuit Breakers
ABB
110 → 250 V dc, 110 → 415V ac Shunt Trip Shunt trip for use with S200, S200P, S200M, S200S, DS200AC,
Part: 2CDS200909R0002 S2C-A2
Range: System Pro M Compact
Series: S2C
For Use With: S200, S200P, S200M, S200S, DS200AC, DS200A, DS200MAC, DS200MA
Schneider Electric
Circuit Trip for use with Nsx100..630
Part: LV434212
Range: Compact
Series: LV4
For Use With: Nsx100..630
Siemens
Push Button Circuit Trip for use with Standard rail mounting
Part: 5TE4812
Range: Sentron
Current Rating: 20A
Series: 5TE4
Schneider Electric
Shunt trip for use with Multi 9 C60 C60BP, Multi 9 C60 C60BPR, Multi 9 C60 C60SP, Multi 9 C60H-DC, Multi 9 GFP
Part: M9A26946
Range: Multi 9
Current Rating: 6A
Series: M9A
Dold
Remote Switch Control Station Switch
Part: IK8800.11 AC50Hz 230V
Current Rating: 16A
Series: IK 8800
Type: Remote Switch
Siemens
24V dc Undervoltage Release Circuit Trip for use with 3RV2 Series Circuit Breakers
Part: 3RV2902-1AB4
Range: SIRIUS
Series: 3RV2
For Use With: 3RV2 Series Circuit Breakers
Siemens
90 → 110V ac Shunt Trip Circuit Trip for use with 3RV2 Series Circuit Breakers
Part: 3RV2902-1DF0
Range: SIRIUS
Series: 3RV2
For Use With: 3RV2 Series Circuit Breakers
Lovato
Shunt Trip Shunt trip for use with P1MB Series
Part: P1X16230
Range: ModuLo
Current Rating: 3 A, 6A
Series: P1X
Schneider Electric
Circuit Trip for use with Multi 9 C60 C60BP, Multi 9 C60 C60BPR, Multi 9 C60 C60SP, Multi 9 C60H-DC, Multi 9 GFP
Part: M9A26969
Range: Multi 9
Series: M9A
For Use With: Multi 9 C60 C60BP, Multi 9 C60 C60BPR, Multi 9 C60 C60SP, Multi 9 C60H-DC, Multi 9 GFP
ABB
Shunt Trip Shunt trip for use with Tmax XT1, Tmax XT2, Tmax XT3, Tmax XT4
Part: 66314
Range: SACE Tmax XT
Series: SOR XT1-XT4
For Use With: Tmax XT1, Tmax XT2, Tmax XT3, Tmax XT4
Schneider Electric
100V ac Shunt Trip Circuit Trip for use with IC60, IID, ISW-NA
Part: A9A26946
Range: Acti 9
Current Rating: 1 → 6A
Series: iC60H
Schneider Electric
100 → 415 V ac, 110 → 130V dc Shunt Trip Shunt trip for use with ARA, ic60 MCB, IDPN Vigi, ild Double
Part: A9A26476
Range: Acti 9
Series: iMX
For Use With: ARA, ic60 MCB, IDPN Vigi, ild Double Terminal, ilD MCB, iSW-NA, RCA
Schneider Electric
230V ac Undervoltage Release Circuit Trip for use with C120 Series, C60 Series, ID Residual Current Device, IDPN
Part: A9N26969
Range: Acti 9
Series: MNx
For Use With: C120 Series, C60 Series, ID Residual Current Device, IDPN Residual Current Device
Siemens
90 → 110V ac Shunt Trip Shunt trip for use with 3RV2 Series Circuit Breakers
Part: 3RV2902-2DF0
Range: SIRIUS
Series: 3RV2
For Use With: 3RV2 Series Circuit Breakers